Koolaire Ice Machine Water Loss: SL#1 and SL#2 Flashing

Water Loss means the water trough did not fill within 4 minutes of the inlet valve energizing. The machine stops for 30 minutes and tries again. After 100 consecutive failures it locks out, and the SL#1 and SL#2 lights flash together.

Medium · inspection needed

High: the machine cannot make ice without water and locks out after repeated failures.

Code
Water Loss (SL#1 and SL#2 flashing)
Maker
Koolaire
Equipment
Ice machines
Applies to
Koolaire KT series control board

What does Koolaire Water Loss mean?

Ice is made from a trough of water, so the machine checks that the trough fills. When the inlet valve is energized, the board waits for the water level to be sensed. If the trough has not filled within 4 minutes, the machine stops for 30 minutes and then restarts. This can repeat many times. After 100 consecutive failures, the board locks out and the board shows SL#1 and SL#2 lights flashing at 1-second intervals (Water Loss). The long wait between tries gives a supply problem time to clear, such as a short interruption in the building's water. The manual lists no individual causes in this section. It gives the reset: press the On/Off button and start a new ice making cycle, or switch OFF and then ICE; if it restarts and the condition repeats, call for service. A lockout means the machine tried about two days of waiting.

Affected models and control systems

KT series modular ice machines from Koolaire, the KDT/KYT 0300A, 0400, 0420, 0500, 0700, 1000 and 1700, whatever the cooling type.

Code numbers and their meaning can change between control generations. We match the full model and control before acting on a code.

What you may notice

  • SL#1 and SL#2 flashing together
  • Trough empty or low
  • Machine idle between 30-minute waits

Possible causes

Likely causes — what usually sits behind Water Loss on this control. A technician confirms which one it is before any part is replaced.

  • A building water shutoff valve closed or a supply line frozen
  • A clogged water filter or inlet screen cutting flow below what the trough needs
  • An inlet valve that does not open when energized
  • A float or level sensing part stuck so the board never sees the water

Safe checks before calling for service

✓ What an operator can do
  1. Check that the water supply valve to the machine is open.
  2. Check any external water filter and change it if it is overdue.
  3. Press On/Off and start a new ice making cycle.
  4. If the lights flash again, note whether any water enters the trough and call.

How a technician diagnoses Water Loss

  1. Read the lights and ask when the water was last working.
  2. Measure incoming water pressure and flow.
  3. Check the filter and inlet screen.
  4. Test the inlet valve coil and operation.
  5. Check the water level sensing circuit before replacing the board.
! Leave this to a technician
  • Valve and level sensing circuits run on line voltage near water.
  • Pressure and flow checks need gauges on the supply line.
  • A lockout after 100 failures suggests a firm problem that tests must pin down.

How Water Loss differs from similar codes

Safety Limit 1 and 2 are about freeze and harvest timing; Water Loss shows both lights together and concerns the trough fill.

Technical reference

Maker documentation
Koolaire owner support
Edition
Part Number 000014142 Rev 04 07/22
Models / control
Koolaire KT series control board
Section
Section 3 Operation, Safety Limits (p. 27); Section 5 Troubleshooting, Safety Limit Feature (p. 41)
Checked
October 2026

We use the maker's document to read the code and do not reproduce it. Always confirm the complete model and control before applying these steps.

Water LossQuestions about Koolaire Water Loss
Why does it wait 30 minutes?

It gives a short supply problem time to clear before trying again.

What does a lockout mean?

After 100 consecutive failures, the machine stops trying.

Can I reset it?

Press On/Off and start a new ice making cycle.