Error code · Kolpak · Walk-in coolers & freezers

Kolpak Walk-In Cooler Error Code MONITOR TEMP2 SENSOR ALARM: Temp 2 Open or Shorted

MONITOR TEMP2 SENSOR ALARM means the Temp 2 input is shorted or open. On the stand-alone Display, that input is being used as a monitor sensor and cannot be read. Check the active alarms in the Alarms & Variables menu and have the sensor circuit tested.

Medium · inspection needed

Low: one monitor reading is lost, and the manual does not say cooling stops.

Code
MONITOR TEMP2 SENSOR ALARM
Maker
Kolpak
Equipment
Walk-in coolers & freezers
Applies to
ArcticFox Deluxe Display, stand-alone

What does Kolpak MONITOR TEMP2 SENSOR ALARM mean?

The stand-alone Deluxe Display has three temperature inputs, and Temp 2 can be used either as a room sensor or as a monitor sensor. The monitor role is meant to watch some other spot, such as product or a shelf. Here the manual's wording for the alarm is MONITOR TEMP2 SENSOR ALARM, and its meaning is that the Temp 2 input is shorted or open. In that state there is no real resistance reading to convert to a temperature. The Display flags it as a text alarm in the Alarms & Variables menu. Notice that the manual gives the same meaning for ROOMTEMP2 SENSOR ALARM; the name changes with how the input is used, and the electrical condition does not. The manual lists a DISP CLEAR ALARM variable to clear alarms set in the Display but gives no causes or repair steps.

Affected models and control systems

ArcticFox Deluxe Display, stand-alone, on Kolpak walk-ins. The manual lists this alarm in the Alarms & Variables menu on page 9 of the stand-alone section.

Code numbers and their meaning can change between control generations. We match the full model and control before acting on a code.

What you may notice

  • MONITOR TEMP2 SENSOR ALARM in the Alarms & Variables menu
  • Alarm indication on the Display
  • No monitor temperature shown
  • High and low monitor alarms not working

Possible causes

Likely causes — what usually sits behind MONITOR TEMP2 SENSOR ALARM on this control. A technician confirms which one it is before any part is replaced.

  • Monitor sensor on Temp 2 disconnected or its lead cut
  • Lead squeezed or rubbed through by moving shelving
  • Water in the probe or connector
  • Temp 2 assigned as a monitor input but the sensor never fitted

Safe checks before calling for service

✓ What an operator can do
  1. Scroll the Alarms & Variables menu to see which alarms are active.
  2. Check the monitored area with a thermometer and compare with what the Display shows.
  3. Look at the visible lead for damage. Do not unplug or cut anything.
  4. Report the alarm names and your thermometer reading to the technician.

How a technician diagnoses MONITOR TEMP2 SENSOR ALARM

  1. Read the active alarms and confirm Temp 2 is set up as a monitor input.
  2. Inspect the sensor and lead.
  3. Measure resistance at the sensor and compare with the chart, then test continuity and isolation.
  4. Repair or replace the sensor and lead.
  5. Clear the alarm and confirm no return.
! Leave this to a technician
  • The lead terminals sit inside the powered Display.
  • The monitor sensor may be protecting product, so accurate repair matters.
  • Clearing the alarm without repair only hides it.

Technical reference

Document
ArcticFox Deluxe Display - Original Instructions, Installation, Operation and Maintenance Manual
Edition
Part No. 500002385-4, 5/23
Models / control
ArcticFox Deluxe Display, stand-alone
Section
Deluxe Display - Stand Alone - Alarms & Variables Menu, p.9
Checked
October 2026

We use the maker's document to read the code and do not reproduce it. Always confirm the complete model and control before applying these steps.

MONITOR TEMP2 SENSOR ALARMQuestions about Kolpak MONITOR TEMP2 SENSOR ALARM
Why does the manual list the same meaning for ROOMTEMP2 SENSOR ALARM?

The condition is the same, a shorted or open Temp 2 input. The name reflects how the input is used.

Do the high and low monitor alarms still work?

They depend on a valid reading, so they cannot work while the input is shorted or open.

Is the monitored product at risk?

The alarm does not measure temperature. Check the area with a thermometer.