Kolpak Walk-In Cooler Error Code LOW MONITOR TEMP2 ALARM: Temp 2 Below Offset

LOW MONITOR TEMP2 ALARM means Temp 2 is below the Low Temp Alarm Offset for longer than the Low Temp Alarm Delay. The monitored spot is colder than its limit. Scroll the Alarms & Variables menu to see it, and check the area with a thermometer.

Medium · inspection needed

Medium: a monitored area is below its low alarm point, which can freeze product.

Code
LOW MONITOR TEMP2 ALARM
Maker
Kolpak
Equipment
Walk-in coolers & freezers
Applies to
ArcticFox Deluxe Display, stand-alone

What does Kolpak LOW MONITOR TEMP2 ALARM mean?

On the stand-alone Display, Temp 2 has a low alarm limit based on the Low Temp Alarm Offset. When the reading falls below that limit, a timer starts using the Low Temp Alarm Delay. If the reading stays low for longer than the delay, the text alarm LOW MONITOR TEMP2 ALARM appears in the Alarms & Variables menu. A brief dip is therefore ignored. The alarm is a temperature alarm rather than a wiring alarm, because it needs a valid reading. The manual lists no causes. In a cooler a low reading can mean product near the sensor is at risk of freezing, and in some rooms it is only a sign the sensor is in a cold draft. The manual lists a DISP CLEAR ALARM variable to clear alarms set in the Deluxe Display, and says to scroll the menu to see the active alarms.

Affected models and control systems

ArcticFox Deluxe Display, stand-alone, on Kolpak walk-ins. The manual lists this alarm in the Alarms & Variables menu on page 9 of the stand-alone section.

Code numbers and their meaning can change between control generations. We match the full model and control before acting on a code.

What you may notice

  • LOW MONITOR TEMP2 ALARM in the Alarms & Variables menu
  • Alarm indication on the Display
  • Temp 2 well below normal
  • Frozen items near the sensor

Possible causes

Likely causes — what usually sits behind LOW MONITOR TEMP2 ALARM on this control. A technician confirms which one it is before any part is replaced.

  • Sensor in the direct blast of cold air from the evaporator
  • Room running colder than its setpoint
  • Low Temp Alarm Offset set too close to the normal temperature
  • Cold product against the sensor

Safe checks before calling for service

✓ What an operator can do
  1. Scroll the Alarms & Variables menu to see active alarms and note the Temp 2 value.
  2. Check the area with a separate thermometer and move product that may freeze.
  3. Keep airflow clear and see that nothing is directing cold air at the sensor.
  4. Report the display value, thermometer reading and time to the technician.

How a technician diagnoses LOW MONITOR TEMP2 ALARM

  1. Read the Low Temp Alarm Offset and Low Temp Alarm Delay.
  2. Compare the Temp 2 reading with a thermometer at the sensor.
  3. Check room setpoint and evaporator airflow.
  4. Review sensor placement.
  5. Correct the cause, clear the alarm and watch for return.
! Leave this to a technician
  • Cooling changes can involve live fans and the refrigeration circuit.
  • Offset and delay values are programming linked to the design of the room.
  • Sensor tests need a meter on live inputs.

Technical reference

Document
ArcticFox Deluxe Display - Original Instructions, Installation, Operation and Maintenance Manual
Edition
Part No. 500002385-4, 5/23
Models / control
ArcticFox Deluxe Display, stand-alone
Section
Deluxe Display - Stand Alone - Alarms & Variables Menu, p.9
Checked
October 2026

We use the maker's document to read the code and do not reproduce it. Always confirm the complete model and control before applying these steps.

LOW MONITOR TEMP2 ALARMQuestions about Kolpak LOW MONITOR TEMP2 ALARM
Is this the same as LOW MONITOR TEMP2?

The condition is similar. That name is for the OEM controller with Display. This one is the stand-alone Display alarm.

Why a delay before alarming?

The Display waits for the Low Temp Alarm Delay so that a short dip does not alarm.

Will clearing it stop it returning?

No. If the area is still too cold the alarm returns after clearing.