Error code · Glastender · Bar refrigeration

Glastender Bar Refrigerator Error Code Err 3: Probe Signal Missing

Err 3 is listed in the manual together with Err 1 and has the same two causes. It usually points to controller wires that came unplugged, or to a defective temperature probe. Have the wires reconnected per the wiring diagram in the manual, and call for service if the probe is defective.

Medium · inspection needed

High: without a working probe the controller cannot control cabinet temperature.

Code
Err 3
Maker
Glastender
Equipment
Bar refrigeration
Applies to
C1SB, C2SB, C1SL, C1SU, F1SB, F1SL with digital controller

What does Glastender error code Err 3 mean?

Err 3 shares a row with Err 1 in the troubleshooting table of the Glastender operation manual. The controller uses one temperature sensing probe to know how cold the box is, and Err 3 appears when that input is not working as it should. The manual's definition is brief: it gives the same causes as Err 1 and says that, like Err 1, it usually points to disconnected controller wires. The causes it lists are probe wires disconnected from the digital controller and a defective probe. The actions are also brief. It tells you to reconnect the wires, following the wiring diagram in the operation manual, and to call for service if the probe is defective. The manual does not explain how Err 3 differs from Err 1 in the controller's logic, so we do not either. What can be said is that the controller depends on the probe for cooling decisions, and the code means that dependence has been interrupted.

Affected models and control systems

Glastender bar refrigerators with a digital controller covered by Operation Manual OM007: models C1SB, C2SB, C1SL, C1SU, F1SB and F1SL.

Code numbers and their meaning can change between control generations. We match the full model and control before acting on a code.

What you may notice

  • Err 3 shown on the controller instead of a temperature
  • Cooling that does not follow the set temperature
  • Warm product, or ice on the evaporator if the compressor runs without control

Possible causes

Listed in Glastender's documentation

  • Temperature sensing probe wires disconnected from digital controller
  • Defective temperature sensing probe

Other likely causes — what usually sits behind error code Err 3 on this control. A technician confirms which one it is before any part is replaced.

  • Controller plug loosened by vibration or by pushing the unit back against the wall
  • Probe cable pulled tight when shelving or racks were rearranged
  • Damaged probe lead near the evaporator where it is exposed to cold and condensation

Safe checks before calling for service

✓ What an operator can do
  1. Think back over any recent cleaning, moving or service on the bar refrigerator.
  2. Check any visible probe cable for a kink or a pull that could have unplugged it.
  3. Leave the panels closed and make sure the unit is plugged in firmly with a working outlet.
  4. If Err 3 remains after that, call for service.
  5. Report whether Err 3 appeared suddenly or after someone worked on the unit.

How a technician diagnoses error code Err 3

  1. Confirm the code on the controller and note whether any other message appears.
  2. Inspect the probe connection at the controller against the manual's wiring diagram, power off.
  3. Examine the probe lead for damage and moisture at the evaporator end.
  4. Test the probe resistance with a meter and compare it with the cabinet temperature.
  5. Swap in a new probe only when the test fails, then confirm a normal temperature readout.
! Leave this to a technician
  • Access to the controller wiring is behind panels near live line voltage, which is work for a technician.
  • A probe test needs a meter and the right resistance values for this controller.

How error code Err 3 differs from similar codes

Err 1 and Err 3 are grouped together with identical causes in the manual table. The manual describes Err 1 as most often caused by wires unplugged during service and says Err 3 behaves similarly.

Technical reference

Document
Operation Manual OM007: Self-Contained, Side Serviced Coolers and Frosters
Maker documentation
Glastender owner support
Edition
Rev. 06-01-25 OM007
Models / control
C1SB, C2SB, C1SL, C1SU, F1SB, F1SL with digital controller
Section
Digital Controller Operation, p. 2, Digital Controller Trouble Shooting Error Codes
Checked
October 2026

We use the maker's document to read the code and do not reproduce it. Always confirm the complete model and control before applying these steps.

Err 3Questions about Glastender error code Err 3
Is it safe to keep stock in the unit when Err 3 shows?

The controller may not be holding temperature. Check the box with a thermometer and move perishable items if it is warm.

Does Err 3 reset itself?

The manual lists no reset step. It stays while the wires are loose or the probe is defective.

What is the difference from Err 1?

The manual lists the same causes and actions for both. It does not describe a technical difference.