American Dryer Phase 6 Message: No HEAT

No HEAT means the burner did not light after the ignition retries. The dryer runs with no heat for 3 minutes or until below 100 F. Check the gas supply, the ignition module and the burner ignition parts.

Medium · inspection needed

High: the burner does not light and gas is involved, so the dryer is out of service until it is checked.

Code
No HEAT
Maker
American Dryer (ADC)
Equipment
Dryers
Applies to
American Dryer ML-175 and ML-190 with the Phase 6 OPL microprocessor controller (Phase 7 is a separate section of the same manual)

What does American Dryer (ADC) error code No HEAT mean?

When the controller calls for heat, the ignition system tries to light the burner. The standard retry count is 2, so there are up to 3 attempts, with a 1-minute purge between them to clear unburned gas. If the burner has not lit after the last attempt, the Phase 6 OPL controller shows No HEAT and runs the dryer with no heat for 3 minutes or until the temperature falls below 100 F. The manual's action is to check the gas supply, the ignition module and the burner ignition parts. The gas supply is first because a closed valve, an empty supply line or low gas pressure all look the same at the dryer. This differs from bURNER FLAME FAIL, where the burner lit and the flame then went out. Operators see the dryer tumble cold, sometimes after a clicking sound, and a damp load at the end.

Affected models and control systems

American Dryer ML-175 and ML-190 with the Phase 6 OPL microprocessor controller. Phase 7 is a separate section of the same manual and is not covered here.

Code numbers and their meaning can change between control generations. We match the full model and control before acting on a code.

What you may notice

  • No HEAT on the display
  • Dryer tumbles without heat
  • Clicking from the ignition with no flame
  • Load stays damp

Possible causes

Likely causes — what usually sits behind error code No HEAT on this control. A technician confirms which one it is before any part is replaced.

  • Gas supply valve closed or gas pressure low
  • Ignition module not sparking or glowing
  • Burner ports blocked by lint or debris
  • Air in the gas line after a long idle period

Safe checks before calling for service

✓ What an operator can do
  1. Check that the gas supply valve to the dryer is open.
  2. If you smell gas, leave the area, do not touch switches and call the gas utility.
  3. Clean the lint screen and check the exhaust.
  4. Restart once, and if No HEAT returns, call us.

How a technician diagnoses error code No HEAT

  1. Read the message and confirm No HEAT.
  2. Check gas supply and pressure.
  3. Check the ignition module and its output.
  4. Check the burner ignition parts.
  5. Check the retry sequence and purge.
! Leave this to a technician
  • Gas supply, valve and ignition work is for a technician who works on gas appliances.
  • A gas smell is a safety emergency that calls for the gas utility.
  • Ignition tests involve line voltage.

How error code No HEAT differs from similar codes

No HEAT is a burner that never lit; bURNER FLAME FAIL is a flame that lit and went out.

Technical reference

Document
ML-175 / ML-190 Service Manual, Phase 6 / Phase 7 Microprocessor Controls (American Dryer Corporation)
Edition
ADC Part No. 450431-3
Models / control
American Dryer ML-175 and ML-190 with the Phase 6 OPL microprocessor controller (Phase 7 is a separate section of the same manual)
Section
Phase 6 OPL System Diagnostics, Diagnostic (L.E.D. Display) Failure Codes, printed p.21
Checked
October 2026

We use the maker's document to read the code and do not reproduce it. Always confirm the complete model and control before applying these steps.

No HEATQuestions about American Dryer (ADC) error code No HEAT
How many tries does the dryer make?

The standard retry count is 2, up to 3 attempts, with a 1-minute purge between.

What does the dryer do after No HEAT?

It runs with no heat for 3 minutes or until below 100 F.

What if I smell gas?

Leave the area and call the gas utility.