Booking today · Miami, Los Angeles, Houston, New York and San Diego · three-hour arrival windows Independent commercial equipment repair · Every maker on this site Mon–Fri 7:00 AM - 8:00 PM · Sat 8:00 AM - 6:00 PM
(844) 393-0816 Schedule a Visit
Error code · Continental Girbau · Coin & card laundry

Continental Girbau Inteli Washer Error Code 102: No Memory Available

Code 102 means there is no program memory available. Verify the program contents and delete programs or phases you no longer use to free space.

Medium · inspection needed

Low: a programming message; existing programs keep running.

Code
102
Maker
Continental Girbau
Equipment
Coin & card laundry
Applies to
E-Series washer-extractors with Inteli control (sheet names RMG055 and smaller, EH060 and larger)

What does Continental Girbau error code 102 mean?

The Inteli control stores programs in a memory of limited size. When someone enters or copies a program and the memory has no room left for it, the control shows 102 (No memory available). It is a programming message, not a sign that the control has failed. The manual's action is the same as for code 101: verify the program contents and delete unused programs. Code 101 says every program slot is taken, while 102 says the memory itself is out of room, which can happen even when slots remain, for example when programs are long. No individual causes are itemized for this code. The practical fix is housekeeping: review the stored programs, remove the ones nobody uses and shorten any that carry steps they do not need. Writing each program down before deleting it protects the site's settings, because a deleted program cannot be recovered from the washer.

Affected models and control systems

Continental Girbau E-Series washer-extractors with Inteli control, sheet names RMG055 and smaller and EH060 and larger. Washers with Logi, LogiPro or Vended control use ALn alarms instead.

Code numbers and their meaning can change between control generations. We match the full model and control before acting on a code.

What you may notice

  • Code 102 on the display
  • New program cannot be saved
  • Programming stops when memory is filled

Possible causes

Likely causes — what usually sits behind error code 102 on this control. A technician confirms which one it is before any part is replaced.

  • Program memory is full
  • Long programs with many phases using up the space
  • Old versions kept after changes
  • Programs copied from another washer and never trimmed

Safe checks before calling for service

✓ What an operator can do
  1. Review the list of programs and note which are unused.
  2. Write down any program you might want back.
  3. Delete unused programs or phases.
  4. Try saving the new program again.

How a technician diagnoses error code 102

  1. Confirm the code appears while saving a program.
  2. List all stored programs and their lengths.
  3. Back up the settings of any program to be removed.
  4. Delete unused programs and phases.
  5. Save the new program and run it to confirm.
! Leave this to a technician
  • Deleting programs removes the site's chemical and timing settings.
  • Programming access may be limited to supervisors.
  • Repeated memory messages on a lightly programmed washer may suggest a board problem.

How error code 102 differs from similar codes

Code 101 says all slots are used, 102 says memory is full, and 103 says a single program is full.

Technical reference

Document
Inteli Control Error Codes ST-102. R2 E-Series Inteli Control
Edition
7/17/2023
Models / control
E-Series washer-extractors with Inteli control (sheet names RMG055 and smaller, EH060 and larger)
Section
Alarm table, p.1-5
Checked
October 2026

We use the maker's document to read the code and do not reproduce it. Always confirm the complete model and control before applying these steps.

102Questions about Continental Girbau error code 102
Is code 102 a breakdown?

No. It is a programming limit, and the washer keeps running the programs it already has. Only saving something new is blocked.

How is it different from 101?

101 means every slot is used. 102 means the memory has no room left.

What do I delete?

Only programs you are sure are unused, after writing them down. Long programs with many phases use the most memory, so trimming one of them can free more room than deleting several short ones.

Book a visit

Need help with Continental Girbau error code 102?

A technician confirms the cause on site and gives you the price in writing before any work starts.

☎ Call our office ▤ Schedule a Visit