Error code · Elmeco · Slush & frozen drinks

Elmeco Slush Machine Error Code ALARM SOLVED: Alarms Cleared

ALARM SOLVED on an Elmeco First Class slush machine is an information window shown when one or more alarms have been cleared. The manual does not treat it as a malfunction. No action is listed beyond the standard warning to disconnect the power cable.

Medium · inspection needed

Low: an information message; the machine keeps running.

Code
ALARM SOLVED
Maker
Elmeco
Equipment
Slush & frozen drinks
Applies to
Fetco by Elmeco First Class (FC1, FC2, FC3) with Millennium electronic board

What does Elmeco ALARM SOLVED mean?

Most First Class alarms mean something needs attention. ALARM SOLVED is the opposite. After pressing the MENU button for one second while the board blinks, this window tells you that one or more alarms that had been active have been cleared. The manual calls it an information window and says it is not a problem by itself. It gives no causes and no actions, only the standard reminder to disconnect the power cable before working on the machine. So reading it is simple: the board has seen the cause go away and is saying so. The useful question is what alarm was there before. If you did not see the earlier alarm, it may have cleared on its own, for example after a voltage swing settled, or because you corrected a probe or cable. A repeated ALARM SOLVED after a few hours suggests something intermittent is coming and going.

Affected models and control systems

This applies to Fetco by Elmeco First Class machines FC1, FC2 and FC3 with the Millennium electronic board, per manual 344PEL0101.

Code numbers and their meaning can change between control generations. We match the full model and control before acting on a code.

What you may notice

  • The board blinks and ALARM SOLVED shows after pressing MENU
  • The machine runs normally
  • An alarm that was showing earlier has gone

Possible causes

Likely causes — what usually sits behind ALARM SOLVED on this control. A technician confirms which one it is before any part is replaced.

  • One or more previous alarms cleared
  • A voltage swing that settled by itself
  • A loose probe or cable connection that made contact again
  • Product refilled so that the level probe sensed liquid again

Safe checks before calling for service

✓ What an operator can do
  1. Note which alarm you saw before, if any.
  2. If the machine is running normally, no action is required.
  3. If it shows ALARM SOLVED repeatedly, write down the times and what was happening.
  4. Disconnect the power cable first if you plan to touch the machine, as the manual warns.

How a technician diagnoses ALARM SOLVED

  1. Read the alarm history on the board to see which alarm cleared.
  2. Ask when the earlier alarm appeared and what changed.
  3. Check the connection or supply tied to that earlier alarm.
  4. Watch the machine through a full cycle for a repeat.
  5. Correct any recurring cause that is found.
  6. Confirm no new alarm appears.
! Leave this to a technician
  • The alarm that was cleared may point to a live-power or probe problem that needs a meter.
  • Intermittent contact is hard to find without testing the wiring.
  • If the same alarm keeps clearing and returning, the board's inputs need checking.

Technical reference

Document
Fetco by Elmeco First Class Millennium slush machine manual (344PEL0101)
Edition
Posted 10-17-16
Models / control
Fetco by Elmeco First Class (FC1, FC2, FC3) with Millennium electronic board
Section
First Class Problem Solving, p. 17 (alarm functions p. 9-13)
Checked
October 2026

We use the maker's document to read the code and do not reproduce it. Always confirm the complete model and control before applying these steps.

ALARM SOLVEDQuestions about Elmeco ALARM SOLVED
Is ALARM SOLVED an error?

No. The manual calls it an information window shown when alarms have been cleared.

Do I need to do anything?

Not if the machine runs normally. If you are seeing it often, find out which alarm keeps clearing.

Does it mean the machine fixed itself?

It means the board no longer sees the condition. The cause may still come back.