Glastender Bar Refrigerator Error Code Err 3: Probe Signal Missing
Err 3 is listed in the manual together with Err 1 and has the same two causes. It usually points to controller wires that came unplugged, or to a defective temperature probe. Have the wires reconnected per the wiring diagram in the manual, and call for service if the probe is defective.
High: without a working probe the controller cannot control cabinet temperature.
- Code
- Err 3
- Maker
- Glastender
- Equipment
- Bar refrigeration
- Applies to
- C1SB, C2SB, C1SL, C1SU, F1SB, F1SL with digital controller
What does Glastender error code Err 3 mean?
Err 3 shares a row with Err 1 in the troubleshooting table of the Glastender operation manual. The controller uses one temperature sensing probe to know how cold the box is, and Err 3 appears when that input is not working as it should. The manual's definition is brief: it gives the same causes as Err 1 and says that, like Err 1, it usually points to disconnected controller wires. The causes it lists are probe wires disconnected from the digital controller and a defective probe. The actions are also brief. It tells you to reconnect the wires, following the wiring diagram in the operation manual, and to call for service if the probe is defective. The manual does not explain how Err 3 differs from Err 1 in the controller's logic, so we do not either. What can be said is that the controller depends on the probe for cooling decisions, and the code means that dependence has been interrupted.
Affected models and control systems
Glastender bar refrigerators with a digital controller covered by Operation Manual OM007: models C1SB, C2SB, C1SL, C1SU, F1SB and F1SL.
Code numbers and their meaning can change between control generations. We match the full model and control before acting on a code.
What you may notice
- Err 3 shown on the controller instead of a temperature
- Cooling that does not follow the set temperature
- Warm product, or ice on the evaporator if the compressor runs without control
Possible causes
Listed in Glastender's documentation
- Temperature sensing probe wires disconnected from digital controller
- Defective temperature sensing probe
Other likely causes — what usually sits behind error code Err 3 on this control. A technician confirms which one it is before any part is replaced.
- Controller plug loosened by vibration or by pushing the unit back against the wall
- Probe cable pulled tight when shelving or racks were rearranged
- Damaged probe lead near the evaporator where it is exposed to cold and condensation
Safe checks before calling for service
- Think back over any recent cleaning, moving or service on the bar refrigerator.
- Check any visible probe cable for a kink or a pull that could have unplugged it.
- Leave the panels closed and make sure the unit is plugged in firmly with a working outlet.
- If Err 3 remains after that, call for service.
- Report whether Err 3 appeared suddenly or after someone worked on the unit.
How a technician diagnoses error code Err 3
- Confirm the code on the controller and note whether any other message appears.
- Inspect the probe connection at the controller against the manual's wiring diagram, power off.
- Examine the probe lead for damage and moisture at the evaporator end.
- Test the probe resistance with a meter and compare it with the cabinet temperature.
- Swap in a new probe only when the test fails, then confirm a normal temperature readout.
- Access to the controller wiring is behind panels near live line voltage, which is work for a technician.
- A probe test needs a meter and the right resistance values for this controller.
How error code Err 3 differs from similar codes
Err 1 and Err 3 are grouped together with identical causes in the manual table. The manual describes Err 1 as most often caused by wires unplugged during service and says Err 3 behaves similarly.
Technical reference
- Document
- Operation Manual OM007: Self-Contained, Side Serviced Coolers and Frosters
- Maker documentation
- Glastender owner support
- Edition
- Rev. 06-01-25 OM007
- Models / control
- C1SB, C2SB, C1SL, C1SU, F1SB, F1SL with digital controller
- Section
- Digital Controller Operation, p. 2, Digital Controller Trouble Shooting Error Codes
- Checked
- October 2026
We use the maker's document to read the code and do not reproduce it. Always confirm the complete model and control before applying these steps.
Related Glastender bar refrigeration error codes
Is it safe to keep stock in the unit when Err 3 shows?
The controller may not be holding temperature. Check the box with a thermometer and move perishable items if it is warm.
Does Err 3 reset itself?
The manual lists no reset step. It stays while the wires are loose or the probe is defective.
What is the difference from Err 1?
The manual lists the same causes and actions for both. It does not describe a technical difference.