Booking today · Miami, Los Angeles, Houston, New York and San Diego · three-hour arrival windows Independent commercial equipment repair · Every maker on this site Mon–Fri 7:00 AM - 8:00 PM · Sat 8:00 AM - 6:00 PM
(844) 393-0816 Schedule a Visit
Error code · Hobart · Dish machines

Hobart Commercial Dishwasher Error Code BOOSTER TEMP SENSOR: Open/Short

BOOSTER TEMP SENSOR with Service Required and OPEN or SHORT on a Hobart LXeH or LXeR dishwasher means the booster temperature probe is out of range. The machine continues to run cycles. Call service.

Medium · inspection needed

Medium: the machine keeps running but the booster temperature is not verified.

Code
BOOSTER TEMP SENSOR - Service Required - OPEN or SHORT
Maker
Hobart
Equipment
Dish machines
Applies to
LXeH, LXeR only

What does Hobart BOOSTER TEMP SENSOR - Service Required - OPEN mean?

The booster heats water to the final rinse temperature, and its probe lets the control confirm that it got there. If the probe circuit reads open or shorted, the display shows BOOSTER TEMP SENSOR / Service Required (Service Phone Number) / OPEN or SHORT. This message applies only to the LXeH and LXeR, which have the booster. The machine continues to run cycles, but without a valid booster temperature the control cannot check or regulate the rinse heat, and the final rinse may be too cool, which can show up as LOW RINSE TEMP. The manual's action is to call service, since the probe is part of the heating circuit inside the machine. The sensor message tells you the measuring probe is the problem, not necessarily the heater itself. In practice a technician first proves the probe against a thermometer, because a good heater with a bad probe looks the same on the display as a weak heater, and the repair is very different. Steam, heat cycling and mineral scale around the booster are the usual reasons these probes age.

Affected models and control systems

Hobart LXeH (ML-130192) and LXeR (ML-130194) only, the models with the booster.

Code numbers and their meaning can change between control generations. We match the full model and control before acting on a code.

What you may notice

  • BOOSTER TEMP SENSOR Service Required on the display
  • OPEN or SHORT beneath the message
  • Rinse that feels cooler or inconsistent

Possible causes

Likely causes — what usually sits behind BOOSTER TEMP SENSOR - Service Required - OPEN on this control. A technician confirms which one it is before any part is replaced.

  • Booster temperature probe out of range
  • Probe lead damaged near the booster tank
  • Corroded probe connector
  • Probe element failing
  • Scale around the probe seat

Safe checks before calling for service

✓ What an operator can do
  1. Note whether the display says OPEN or SHORT.
  2. Write down the service number on the display.
  3. Keep panels closed.
  4. Watch whether LOW RINSE TEMP appears as well and tell us.

How a technician diagnoses BOOSTER TEMP SENSOR - Service Required - OPEN

  1. Confirm OPEN or SHORT from the display.
  2. Measure the probe resistance and compare it with the maker's chart.
  3. Inspect the probe lead, connector and seat for corrosion or scale.
  4. Check the booster heater is not the real fault by measuring its current and rinse temperature.
  5. Replace the probe or wiring and verify the rinse temperature.
! Leave this to a technician
  • The booster circuit carries high current at 208-240 V and the booster tank is hot and pressurized.
  • Reading the probe against a chart takes a meter and the maker's data.

How BOOSTER TEMP SENSOR - Service Required - OPEN differs from similar codes

BOOSTER TEMP SENSOR applies only to the LXeH and LXeR, whereas WASH and RINSE TEMP SENSOR messages apply across the LXe range.

Technical reference

Maker documentation
Hobart owner support
Edition
FORM 38435 (March 2014)
Models / control
LXeH, LXeR only
Section
DIAGNOSTIC/ERROR MESSAGES (page 27)
Checked
October 2026

We use the maker's document to read the code and do not reproduce it. Always confirm the complete model and control before applying these steps.

BOOSTER TEMP SENSOR - Service Required - OPENQuestions about Hobart BOOSTER TEMP SENSOR - Service Required - OPEN
Does my LXeC show BOOSTER TEMP SENSOR?

No. The message applies only to the LXeH and LXeR.

Is the booster heater broken?

Not necessarily. The message is about the probe that measures its temperature.

Can the machine keep running?

It continues to run cycles, but the rinse temperature is not being verified.

Book a visit

Need help with Hobart BOOSTER TEMP SENSOR - Service Required - OPEN?

A technician confirms the cause on site and gives you the price in writing before any work starts.

☎ Call our office ▤ Schedule a Visit