Kolpak Walk-In Cooler Error Code DOOR TEMP SENSOR ALARM: Temp 1 Open or Shorted
DOOR TEMP SENSOR ALARM means the Temp 1 input is shorted or open. On the stand-alone Display, Temp 1 reads the door temperature sensor, so that reading is lost. Scroll the Alarms & Variables menu to see active alarms and have the sensor and lead tested.
Low: the door temperature reading is lost, and the manual does not say cooling stops.
- Code
- DOOR TEMP SENSOR ALARM
- Maker
- Kolpak
- Equipment
- Walk-in coolers & freezers
- Applies to
- ArcticFox Deluxe Display, stand-alone
What does Kolpak DOOR TEMP SENSOR ALARM mean?
On the stand-alone Deluxe Display, the first temperature input, Temp 1, is the one used for the door temperature sensor. The Display checks that circuit each time it reads. If the input is shorted, or open because of a broken lead or an unplugged sensor, there is no usable resistance reading and no door temperature. The Display then posts the text alarm DOOR TEMP SENSOR ALARM in the Alarms & Variables menu. The manual gives only that meaning, Temp 1 input shorted or open, and does not list causes. The high and low door temperature alarms need a valid door reading, so they cannot act while this alarm is active. The alarm does not say the door is warm or cold. The manual lists a DISP CLEAR ALARM variable for clearing alarms set in the Display.
Affected models and control systems
ArcticFox Deluxe Display, stand-alone, on Kolpak walk-ins. The manual lists this alarm in the Alarms & Variables menu on page 9 of the stand-alone section.
Code numbers and their meaning can change between control generations. We match the full model and control before acting on a code.
What you may notice
- DOOR TEMP SENSOR ALARM in the Alarms & Variables menu
- Alarm indication on the Display
- No door temperature shown
- Door temperature alarms silent
Possible causes
Likely causes — what usually sits behind DOOR TEMP SENSOR ALARM on this control. A technician confirms which one it is before any part is replaced.
- Door temperature sensor on Temp 1 unplugged or its lead broken
- Lead worn through where it crosses the door frame
- Moisture in the sensor or connector at the door
- Temp 1 used for door temperature with no sensor fitted
Safe checks before calling for service
- Scroll the Alarms & Variables menu to see active alarms.
- Check the door area with a thermometer.
- Look at the lead near the door frame for damage, without pulling it.
- Tell the technician the alarm name and the time it started.
How a technician diagnoses DOOR TEMP SENSOR ALARM
- Read the active alarms and the Temp 1 setup.
- Inspect the sensor, lead and frame crossing.
- Measure resistance against the chart and check continuity and isolation.
- Repair or replace.
- Clear the alarm and confirm door temperature reads normally.
- The lead ends in the powered Display housing.
- Frame-crossing leads may need rerouting so they survive door movement.
- Clearing the alarm without repair hides the problem.
Technical reference
- Document
- ArcticFox Deluxe Display - Original Instructions, Installation, Operation and Maintenance Manual
- Edition
- Part No. 500002385-4, 5/23
- Models / control
- ArcticFox Deluxe Display, stand-alone
- Section
- Deluxe Display - Stand Alone - Alarms & Variables Menu, p.9
- Checked
- October 2026
We use the maker's document to read the code and do not reproduce it. Always confirm the complete model and control before applying these steps.
Related Kolpak walk-in cooler & freezer error codes
Why Temp 1?
The manual lists Temp 1 as the input this alarm refers to. It is the door temperature sensor on the stand-alone Display.
Is this the same as DOOR TEMP SENSOR?
The condition is alike. DOOR TEMP SENSOR is for the OEM controller with Display AUX1. This alarm is for the stand-alone Display.
Does it affect the door alarms?
Yes. HIGH DOOR TEMP ALARM and LOW DOOR TEMP ALARM need a valid door reading.