Error code · Kolpak · Walk-in coolers & freezers

Kolpak Walk-In Cooler Error Code LOW MONITOR TEMP3 ALARM: Temp 3 Below Offset

LOW MONITOR TEMP3 ALARM means Temp 3 is below the Low Temp Alarm Offset for longer than the Low Temp Alarm Delay. The third monitored spot is colder than its low limit. Scroll the Alarms & Variables menu to confirm and check that area with a thermometer.

Medium · inspection needed

Medium: a monitored area is below its low alarm point, which can freeze product.

Code
LOW MONITOR TEMP3 ALARM
Maker
Kolpak
Equipment
Walk-in coolers & freezers
Applies to
ArcticFox Deluxe Display, stand-alone

What does Kolpak LOW MONITOR TEMP3 ALARM mean?

For Temp 3 the stand-alone Display has a low limit set by the Low Temp Alarm Offset. Reading under that limit starts a timer, the Low Temp Alarm Delay. If the reading is still low when it ends, the text alarm LOW MONITOR TEMP3 ALARM appears in the Alarms & Variables menu. Dips shorter than the delay are ignored. As with the other monitor alarms, this one needs a valid reading, so the sensor circuit is healthy and the temperature itself is the issue. The manual gives no causes and does not name what Temp 3 monitors. A cold spot can freeze produce or drinks, though in a freezer the limit may be set so low that the alarm points to a real problem. The manual mentions the DISP CLEAR ALARM variable for clearing alarms set in the Display.

Affected models and control systems

ArcticFox Deluxe Display, stand-alone, on Kolpak walk-ins. The manual lists this alarm in the Alarms & Variables menu on page 9 of the stand-alone section.

Code numbers and their meaning can change between control generations. We match the full model and control before acting on a code.

What you may notice

  • LOW MONITOR TEMP3 ALARM in the Alarms & Variables menu
  • Alarm indication on the Display
  • Temp 3 reading under its low limit
  • Ice or frozen product at the sensor

Possible causes

Likely causes — what usually sits behind LOW MONITOR TEMP3 ALARM on this control. A technician confirms which one it is before any part is replaced.

  • Sensor sitting in the cold air stream from the evaporator
  • Whole room colder than its setpoint
  • Low Temp Alarm Offset set close to the normal temperature
  • Cold product touching the probe

Safe checks before calling for service

✓ What an operator can do
  1. Scroll the Alarms & Variables menu to confirm the alarm and note Temp 3.
  2. Measure the area with a thermometer and move product that could freeze.
  3. Keep airflow clear and see that cold air is not blowing straight at the sensor.
  4. Report the readings and time to the technician.

How a technician diagnoses LOW MONITOR TEMP3 ALARM

  1. Read the Low Temp Alarm Offset and Low Temp Alarm Delay.
  2. Compare Temp 3 with a thermometer.
  3. Check room setpoint and evaporator airflow.
  4. Review sensor placement.
  5. Correct the cause, clear the alarm and observe.
! Leave this to a technician
  • Cooling adjustments can involve live fans and refrigerant circuits.
  • Offset and delay values are programming tied to the room design.
  • Sensor tests put a meter on live inputs.

Technical reference

Document
ArcticFox Deluxe Display - Original Instructions, Installation, Operation and Maintenance Manual
Edition
Part No. 500002385-4, 5/23
Models / control
ArcticFox Deluxe Display, stand-alone
Section
Deluxe Display - Stand Alone - Alarms & Variables Menu, p.9
Checked
October 2026

We use the maker's document to read the code and do not reproduce it. Always confirm the complete model and control before applying these steps.

LOW MONITOR TEMP3 ALARMQuestions about Kolpak LOW MONITOR TEMP3 ALARM
Is this alarm the opposite of HIGH MONITOR TEMP3 ALARM?

Yes. One watches for a reading above its offset. This one watches for a reading below its offset.

Do I need to act at once?

Check the area temperature and move anything that could freeze. The manual states no other urgent action.

Will clearing the alarm stop it?

Only if the area has warmed back above the limit. Otherwise it returns.