Kolpak Walk-In Cooler Error Code LOW MONITOR TEMP3: Monitor3 Below Limit
LOW MONITOR TEMP3 means the Display Monitor3 temperature is below MON TMP3 LO ALRM for longer than MON TMP3 AL DLY. The third monitored spot is colder than its low limit. Press ENTER to silence the alarm for one hour and find out why that area is running cold.
Medium: a monitored area is colder than its low limit, which can freeze product.
- Code
- LOW MONITOR TEMP3
- Maker
- Kolpak
- Equipment
- Walk-in coolers & freezers
- Applies to
- ArcticFox OEM Controller with Deluxe Display (Kolpak walk-ins)
What does Kolpak LOW MONITOR TEMP3 mean?
Monitor3 is one of the extra temperature inputs on the Deluxe Display, and it has a low limit named MON TMP3 LO ALRM. The controller reads the sensor and compares the value with that limit. If the temperature is below it, a timer begins. When the reading has stayed below the limit for longer than MON TMP3 AL DLY, the text alarm LOW MONITOR TEMP3 appears in the Alarms menu. A short dip, for example in a cold draft during defrost recovery, is ignored. The manual states no causes and does not describe any change to cooling when the alarm is raised. Whatever area Monitor3 watches is simply colder than the setting allows. In a cooler that can mean frozen produce or drinks; in a freezer it may be harmless, depending on the limit. The alarm sounds again after one hour if the reading stays low.
Affected models and control systems
ArcticFox OEM Controller with Deluxe Display on Kolpak walk-ins. The manual lists LOW MONITOR TEMP3 in the Alarms menu on page 17. It needs a Monitor3 sensor.
Code numbers and their meaning can change between control generations. We match the full model and control before acting on a code.
What you may notice
- LOW MONITOR TEMP3 text in the Alarms menu
- Audible alarm from the display
- Monitor3 reading below its usual value
- Frozen or icy product near the Monitor3 sensor
Possible causes
Likely causes — what usually sits behind LOW MONITOR TEMP3 on this control. A technician confirms which one it is before any part is replaced.
- Sensor sitting in a direct cold air stream from the evaporator
- Room running colder than its setpoint so every sensor reads low
- Low limit MON TMP3 LO ALRM raised above the area's normal temperature
- Very cold product touching the sensor or its probe
Safe checks before calling for service
- Press ENTER to silence the alarm. It stays quiet for 1 hour and returns if the reading stays low.
- Find the Monitor3 location and check the temperature with a thermometer.
- Move delicate product that could freeze, and keep airflow clear.
- Record the display reading and the time of the alarm for the technician.
How a technician diagnoses LOW MONITOR TEMP3
- Read MON TMP3 LO ALRM and MON TMP3 AL DLY.
- Compare the Monitor3 reading with a thermometer at the same spot.
- Check the room setpoint, the evaporator airflow and any recent setting changes.
- Check sensor mounting.
- Correct the cooling, the sensor position or the limit and confirm the reading returns above the low limit.
- Cooling adjustments can involve live fan and compressor wiring.
- Alarm limits are programmed values that should match the design of the room.
- A sensor test puts a meter on a live controller input.
Technical reference
- Document
- ArcticFox Deluxe Display - Original Instructions, Installation, Operation and Maintenance Manual
- Edition
- Part No. 500002385-4, 5/23
- Models / control
- ArcticFox OEM Controller with Deluxe Display (Kolpak walk-ins)
- Section
- ArcticFox OEM Controller - Alarms Menu, p.17
- Checked
- October 2026
We use the maker's document to read the code and do not reproduce it. Always confirm the complete model and control before applying these steps.
Related Kolpak walk-in cooler & freezer error codes
Is LOW MONITOR TEMP3 only for coolers?
No. It compares the reading with MON TMP3 LO ALRM, whatever that is set to. In a freezer the limit would be far lower.
Why does it say longer than a delay?
The controller waits for MON TMP3 AL DLY so that short dips do not trigger an alarm.
Will it return after I silence it?
Yes, after one hour, unless the reading has come back above the low limit.