Error code · Continental Girbau · Coin & card laundry

Continental Girbau Washer Error Code ALn / U-39, U-41 to U-43, U-50, U-52, U-56

These U codes are inverter output and motor alarms: an internal inverter problem, a problem on one motor phase, a short in the motor or a short that trips the main breaker. Power the washer off for five minutes, as the manual advises, then restart once. If it returns, a technician must test the motor and inverter.

Medium · inspection needed

High: these alarms indicate a short or inverter failure, and the washer must stay off until tested.

Code
ALn / U-39, U-41, U-42, U-43, U-50, U-52, U-56
Maker
Continental Girbau
Equipment
Coin & card laundry
Applies to
E-Series washer-extractors with Logi / LogiPro / Vended control

What does Continental Girbau error code ALn / U-39 mean?

This row groups seven numbers that each describe a different part of the inverter-to-motor path. U-39 is an internal inverter control problem. U-41, U-42 and U-43 each point to one of the three output phases going to the motor. U-50 and U-52 report a short in the motor or its windings, phase to phase, to the housing or at a klixon. U-56 is a short large enough to trip the main breaker. When the inverter detects one of these conditions it stops driving the motor, and the control displays the matching ALn / U- number. The manual's checks are the same for the group: input voltage in range with no brown-out, supply voltage to the KA1 relay, a clean inverter, motor wiring, the discharge resistor and earth, powering off for 5 minutes to reset, and measuring the U-V-W phase voltages and motor windings. Its causes are a brown-out or bad supply, a shorted motor or cable, and a bad inverter.

Affected models and control systems

Continental Girbau E-Series washer-extractors with Logi, LogiPro or Vended control, sheet names EH020, EM025, EH060, RMG055 and smaller. The sheet does not name the inverter brand.

Code numbers and their meaning can change between control generations. We match the full model and control before acting on a code.

What you may notice

  • One of the listed U codes shows on the display
  • Main breaker trips with U-56
  • Motor hums but the drum does not turn

Possible causes

Listed in Continental Girbau's documentation

  • Brown-out or bad supply
  • Shorted motor or cable
  • Bad inverter

Other likely causes — what usually sits behind error code ALn / U-39 on this control. A technician confirms which one it is before any part is replaced.

  • Motor cable insulation chafed where it passes the frame
  • Moisture from a leak or a flooded cabinet reaching the motor terminals
  • Damaged klixon wiring inside the motor

Safe checks before calling for service

✓ What an operator can do
  1. Press stop and let the drum come to rest, then switch the washer off at its disconnect.
  2. Leave it off for 5 minutes, as the manual advises, then restart once.
  3. If a breaker tripped, do not keep resetting it. Check for water around the washer and leave the panels closed.
  4. Write down which U number appeared and whether the breaker tripped.

How a technician diagnoses error code ALn / U-39

  1. Identify which U code is displayed and read the matching part of the ST-101 table.
  2. Confirm input voltage is in range and there was no brown-out, and check the KA1 supply.
  3. Check the discharge resistor and earth, and clean the inverter.
  4. Inspect the motor wiring and measure U-V-W phase voltages.
  5. Test the motor windings phase to phase and to the housing.
  6. Replace the motor, cable or inverter based on the readings.
! Leave this to a technician
  • A breaker that trips on a short can mean a dangerous surge of current, so repeated resets are unsafe.
  • Phase and winding tests are done on 208-240 V or higher conductors.
  • Telling a shorted motor from a failed inverter needs insulation and continuity measurements.

How error code ALn / U-39 differs from similar codes

U-39 is an internal inverter alarm, U-41 to U-43 are single-phase alarms, U-50 and U-52 are motor shorts and U-56 trips the main breaker.

Technical reference

Edition
3/18/24
Models / control
E-Series washer-extractors with Logi / LogiPro / Vended control
Section
Alarm table, p.1-6
Checked
October 2026

We use the maker's document to read the code and do not reproduce it. Always confirm the complete model and control before applying these steps.

ALn / U-39Questions about Continental Girbau error code ALn / U-39
Do all of these codes mean the same thing?

No. They are grouped on one row, but each points to a different place in the inverter-to-motor path.

Why wait five minutes?

The manual advises power off for 5 minutes to reset the inverter. A shorter wait may not reset it.

Can I reset the breaker after U-56?

Not repeatedly. A short that trips the breaker needs to be found before the washer runs again.