Error code · Continental Girbau · Coin & card laundry

Continental Girbau Inteli Washer Error Code 27: Temperature Probe Failure

Code 27 means the temperature probe has failed or reads out of range. Restart once. If code 27 returns, a technician checks the thermistor, its wiring and the heating relay or steam valves.

Medium · inspection needed

Medium: the washer cannot control heating until the probe reading is restored.

Code
27
Maker
Continental Girbau
Equipment
Coin & card laundry
Applies to
E-Series washer-extractors with Inteli control

What does Continental Girbau error code 27 mean?

The bath temperature is measured by a thermistor, a sensor whose resistance changes with temperature. On this washer it is an NTC type, so the resistance falls as the water warms. The control reads that resistance continuously. If the value is missing or impossible, it cannot control the heating and displays 27 (Temp probe failure). The manual's guidance is specific. If the alarm shows at the start of a fill, the thermistor itself is the likely failure; at room temperature it should read about 12 kilohms. The wiring is verified, and the electric relay or steam valves are verified too. The source describes the checks and leaves the causes unnamed. An open circuit in the wiring and a failed thermistor look alike on the display, so a resistance reading at the connector is what separates them. A washer without heating may still run cold programs, but the control often refuses when it cannot read the bath.

Affected models and control systems

Continental Girbau E-Series washer-extractors with Inteli control, sheet names RMG055 and smaller and EH060 and larger. Washers with Logi, LogiPro or Vended control use ALn alarms instead.

Code numbers and their meaning can change between control generations. We match the full model and control before acting on a code.

What you may notice

  • Code 27 on the display
  • Alarm appears right as the fill begins
  • Heated programs do not start

Possible causes

Likely causes — what usually sits behind error code 27 on this control. A technician confirms which one it is before any part is replaced.

  • Probe connector corroded by steam and detergent vapor
  • Wire broken where the probe lead flexes
  • Heating relay stuck, making the bath temperature look wrong to the control

Safe checks before calling for service

✓ What an operator can do
  1. Switch off at the disconnect, leave it a minute and try once more.
  2. Restart and see whether code 27 shows at the beginning of the fill again.
  3. Keep your hands out of the control area.
  4. Note whether the alarm appeared at the start of the fill, since the manual treats that as a clue.

How a technician diagnoses error code 27

  1. Read the code and note when it appears.
  2. Measure the thermistor resistance and compare it with the NTC value, about 12 kilohms at room temperature.
  3. Verify the wiring and connector.
  4. Check the electric relay or steam valves.
  5. Replace the thermistor if its reading is out of range.
! Leave this to a technician
  • Resistance tests require isolating the circuit and comparing readings against a chart.
  • Relay and steam valve checks involve high-amp heating circuits and hot piping.
  • Heating in a washer with a failed probe can overheat the bath.

How error code 27 differs from similar codes

Code 27 is the probe failure and a separate row from 23, 26 and 29, which are temperature alarms in the bath itself.

Technical reference

Edition
7/17/2023
Models / control
E-Series washer-extractors with Inteli control
Section
Alarm table, p.1-5
Checked
October 2026

We use the maker's document to read the code and do not reproduce it. Always confirm the complete model and control before applying these steps.

27Questions about Continental Girbau error code 27
What does about 12 kilohms mean?

It is the NTC thermistor reading at room temperature that the manual gives for a healthy probe.

Can I run cold cycles?

Possibly, but the control may stop on this alarm anyway.

Is it the same as ALn / Prob?

It is the Inteli counterpart of the Logi probe alarm.

Book a visit

Need help with Continental Girbau error code 27?

A technician confirms the cause on site and gives you the price in writing before any work starts.