  1. Case not holding temperature
  2. Condenser fan or compressor not running
  3. Clogged condensing unit
  4. Iced evaporator
  5. Power, breaker or thermostat setting trouble

The PF-SC cases are self-contained multi-deck merchandisers that use R-290, a flammable refrigerant. The PF-54-SC and CF-SC fit bakeries and grab-and-go areas, and run on 115 volts. The recommended troubleshooting order starts with power, the plug and the switch, then the thermostat setting, the overload and a clogged condensing unit.

R-290 comes with a clear rule: do not use mechanical devices to defrost or puncture the tubing. If the evaporator ices up, let it defrost the right way or call us.

We check ambient conditions, the condenser, airflow and loading, then the controls, and we handle sealed system work carefully. Tell us the model number from the label and what the case is doing.

About this series

  • Self-contained multi-deck bakery and merchandiser cases
  • R-290 flammable refrigerant and 115 volt power
  • Thermostat or controller with a temperature setting
  • Models PF-54-SC and CF-SC
  • Designed for stores at 75 F and 55 percent humidity at most
FAQHillphoenix PF-SC R-290 Self-Contained Merchandisers questions
Why must I avoid scraping ice?

R-290 is flammable, and the maker warns against mechanical defrosting. Scraping can puncture tubing near the coil. Call us if the evaporator is iced, and let the case warm up.

What do you check first when it is warm?

Power and the thermostat setting, then a clogged condensing unit and airflow. Those match the maker troubleshooting order and are quick to rule out before deeper work.

Is it designed for any store?

The maker designs it for 75 F and 55 percent humidity at most. A hotter or more humid store makes the case work harder and lets frost build faster.