Error code · Southbend · Convection ovens

Southbend EZ Com Oven Error Code Err GA:S: Gas Error

Err with GA:S on a Southbend EZ Com combination oven is a gas error: the burner did not light or flame was not proven. Make sure the gas valve is open, and call us. If you smell gas, leave the area and call the gas utility.

Medium · inspection needed

High: the gas is shut off for safety, and the oven will not heat until the ignition problem is fixed.

Code
Err + GA:S
Maker
Southbend
Equipment
Convection ovens
Applies to
Southbend EZ Com control

What does Southbend error code Err + GA:S mean?

The GA:S code covers the whole ignition sequence. The controller opens the gas, tries to light the burner with the ignitors, and checks for flame. If flame is not proven, it shows Err in the TEMPERATURE display and GA:S in the TIME display. The manual sends the technician to the Gas Error flowchart on page 30. It starts with the gas valve being open and the supply pressure being above 7 in. W.C. For natural gas and 11 in. W.C. For propane. It then watches the ignitors in the first 101 seconds, checks the ignitor voltage, and inspects the pilots, the orifice and the flame sensor. Manifold pressure should be about 4 in. W.C. For natural gas and 10 in. W.C. For propane, and the gas valve is replaced if it is wrong.

Affected models and control systems

Southbend EZ Com combination ovens CG/12SC and CG/22SC (gas).

Code numbers and their meaning can change between control generations. We match the full model and control before acting on a code.

What you may notice

  • Err shows in the TEMPERATURE display and GA:S in the TIME display
  • The burner does not light
  • You hear ignition attempts and then the oven stops
  • The oven stays cold

Possible causes

Listed in Southbend's documentation

  • Gas shut-off valve closed
  • Low supply pressure
  • Defective or misplaced ignitor
  • Blocked or damaged pilot orifice or supply tube
  • Flame sensor touching metal or misplaced
  • Incorrect manifold pressure
  • Defective gas valve, RAM module or wiring

Other likely causes — what usually sits behind error code Err + GA:S on this control. A technician confirms which one it is before any part is replaced.

  • A gas line shared with other equipment that drops pressure when they fire together
  • Soot or grease buildup on the flame sensor that hides the flame

Safe checks before calling for service

✓ What an operator can do
  1. Check that the gas shutoff valve to the oven is open.
  2. If you smell gas, leave the area immediately and call the gas utility.
  3. Turn the oven off and on once and watch whether the burner lights.
  4. Do not relight or adjust the burner. Note what you heard and saw, and call us.

How a technician diagnoses error code Err + GA:S

  1. Read the code and confirm Err and GA:S.
  2. Confirm the gas valve is open and measure supply pressure against 7 in. W.C. Natural or 11 in. W.C. Propane.
  3. Watch the ignitors in the first 101 seconds.
  4. Check ignitor voltage and the RAM module or ignitor.
  5. Inspect the pilots, orifice and flame sensor.
  6. Check manifold pressure, about 4 in. W.C. Natural or 10 in. W.C. Propane, and replace the gas valve if wrong.
! Leave this to a technician
  • Gas pressure and valve work is gas-fitting work that needs a trained technician.
  • Ignitor voltage checks are done on live circuits.
  • A flame that is not proven must be diagnosed with pressure readings, not by trial.

How error code Err + GA:S differs from similar codes

GA:S is the gas error, unlike FA:n, which concerns the limit and centrifugal switches.

Technical reference

Maker documentation
Southbend owner support
Edition
Part No. 1182851, Rev. 2
Models / control
Southbend EZ Com control
Section
Troubleshooting, Control panel error codes (manual p. 26; Gas Error flowchart p. 30)
Checked
October 2026

We use the maker's document to read the code and do not reproduce it. Always confirm the complete model and control before applying these steps.

Err + GA:SQuestions about Southbend error code Err + GA:S
Is GA:S dangerous?

The oven stops the gas when no flame is proven. If you smell gas, leave and call the gas utility.

Can I relight the pilot?

No. The control handles ignition, and a technician checks it.

Which gas does my oven use?

The pressure targets differ for natural gas and propane, so a technician checks the label.

Book a visit

Need help with Southbend error code Err + GA:S?

A technician confirms the cause on site and gives you the price in writing before any work starts.

☎ Call our office ▤ Schedule a Visit