Hobart Commercial Dishwasher Error Code LOW RINSE TEMP: Rinse Too Cool

LOW RINSE TEMP on a Hobart LXe dishwasher means the rinse water was too cool for three cycles in a row. The machine keeps running cycles. Check the incoming water temperature and supply.

Medium · inspection needed

Medium: the machine keeps running, but a cool final rinse is a hygiene concern.

Code
LOW RINSE TEMP
Maker
Hobart
Equipment
Dish machines
Applies to
LXe Series

What does Hobart LOW RINSE TEMP mean?

The final rinse needs hot water to sanitize and to flash-dry the dishes. The control checks the rinse temperature each cycle. After two consecutive low rinse temperatures, it shows LOW RINSE TEMP if the problem occurs again on the third cycle. The machine continues to run cycles, so it is a warning and not a shutdown. The manual's action is to check the incoming water temperature and the supply, and the table states no other step. That means the cause is usually outside the machine: a hot water heater turned down or running short, a supply valve partly closed, or a long cold line to the kitchen. On heater models the machine's own booster is the other candidate, and for a booster problem the machine shows its own sensor messages. If the incoming water is hot and the message persists, a technician has to look at the rinse heating.

Affected models and control systems

Hobart LXe series: LXeC (ML-130191), LXeH (ML-130192), LXePR (ML-130193) and LXeR (ML-130194).

Code numbers and their meaning can change between control generations. We match the full model and control before acting on a code.

What you may notice

  • LOW RINSE TEMP on the display
  • Dishes that do not dry as well
  • Machine still completing its cycles

Possible causes

Likely causes — what usually sits behind LOW RINSE TEMP on this control. A technician confirms which one it is before any part is replaced.

  • Low rinse temperature on three consecutive cycles
  • Building hot water heater set too low or overloaded at peak times
  • Hot supply valve partly closed
  • Long cold pipe run feeding the dishwasher
  • Booster heating element weak on a booster model

Safe checks before calling for service

✓ What an operator can do
  1. Check that the hot water supply valve to the dishwasher is fully open.
  2. Run hot water at a nearby tap and see how hot it gets.
  3. Note the time of day when the message appears.
  4. Report whether the dishes dry normally and tell us the model.

How a technician diagnoses LOW RINSE TEMP

  1. Read the incoming water temperature at the machine.
  2. Check the supply valve and line strainer.
  3. On booster models check booster operation and rinse temperature at the sensor.
  4. Compare the rinse reading with a thermometer.
  5. Correct the supply or heating part and run cycles to confirm.
! Leave this to a technician
  • Measuring rinse temperature at the probe and testing a booster element involves live 208-240 V heater circuits.
  • The hot water heater itself may belong to a plumber.

How LOW RINSE TEMP differs from similar codes

LOW RINSE TEMP is the first-stage message; after 10 consecutive cycles it changes to include Check Water Input.

Technical reference

Maker documentation
Hobart owner support
Edition
FORM 38435 (March 2014)
Models / control
LXe Series
Section
DIAGNOSTIC/ERROR MESSAGES (page 27)
Checked
October 2026

We use the maker's document to read the code and do not reproduce it. Always confirm the complete model and control before applying these steps.

LOW RINSE TEMPQuestions about Hobart LOW RINSE TEMP
Can I keep washing with LOW RINSE TEMP?

The machine keeps running cycles, but a cool rinse may not sanitize properly, so fix the supply soon.

What triggers the message?

A low rinse temperature on the third consecutive cycle.

Where should I look first?

At the incoming water temperature and supply, as the manual says.