Hobart Commercial Dishwasher Error Code RINSE TEMP SENSOR: Open/Short

RINSE TEMP SENSOR with Service Required and OPEN or SHORT on a Hobart LXe dishwasher means the final rinse temperature probe is out of range. The machine continues to run cycles. Call service.

Medium · inspection needed

Medium: the machine runs but the rinse temperature cannot be confirmed.

Code
RINSE TEMP SENSOR - Service Required - OPEN or SHORT
Maker
Hobart
Equipment
Dish machines
Applies to
LXe Series

What does Hobart RINSE TEMP SENSOR - Service Required - OPEN mean?

The final rinse probe measures the temperature of the water that sanitizes the dishes. The control compares it with the required rinse temperature. If the probe circuit opens or shorts, the reading is out of range and the display shows RINSE TEMP SENSOR / Service Required (Service Phone Number) / OPEN or SHORT. The machine continues to run cycles, so the operator can finish a rush, but the control cannot confirm that the final rinse reached temperature. That is the point of the probe, so the message is more important in a food operation than it may look. It applies to all four LXe models. The manual's action is to call service. Do not confuse it with LOW RINSE TEMP, which is a real measured cool rinse, whereas this message means the measuring itself has failed. Because the rinse probe sits in the hottest, steamiest part of the machine, its lead and connector are exposed to repeated heating and cooling, which is the usual way such a probe ages out.

Affected models and control systems

Hobart LXe series: LXeC (ML-130191), LXeH (ML-130192), LXePR (ML-130193) and LXeR (ML-130194).

Code numbers and their meaning can change between control generations. We match the full model and control before acting on a code.

What you may notice

  • RINSE TEMP SENSOR Service Required on the display
  • OPEN or SHORT beneath the message
  • No reliable rinse temperature reading

Possible causes

Likely causes — what usually sits behind RINSE TEMP SENSOR - Service Required - OPEN on this control. A technician confirms which one it is before any part is replaced.

  • Final rinse temperature probe out of range
  • Probe lead cracked from heat and steam
  • Connector corroded by rinse vapor
  • Probe element drifting or failed
  • Loose probe plug at the control

Safe checks before calling for service

✓ What an operator can do
  1. Note whether OPEN or SHORT is shown.
  2. Write down the service number on screen.
  3. Do not touch the probe or wiring.
  4. Check dish results and temperature with a test strip if your kitchen uses one.

How a technician diagnoses RINSE TEMP SENSOR - Service Required - OPEN

  1. Read the message and confirm OPEN or SHORT.
  2. Measure the probe resistance against the chart.
  3. Inspect the lead, plug and seat for steam damage.
  4. Verify actual rinse temperature with a thermometer.
  5. Replace the probe or repair the wire, then check the readings.
! Leave this to a technician
  • The probe sits in a hot, wet area of a machine fed by 208-240 V.
  • Verifying real rinse temperature independently of the probe takes instruments.

How RINSE TEMP SENSOR - Service Required - OPEN differs from similar codes

RINSE TEMP SENSOR means the probe failed to read; LOW RINSE TEMP means the probe read a rinse that was truly too cool.

Technical reference

Maker documentation
Hobart owner support
Edition
FORM 38435 (March 2014)
Models / control
LXe Series
Section
DIAGNOSTIC/ERROR MESSAGES (page 27)
Checked
October 2026

We use the maker's document to read the code and do not reproduce it. Always confirm the complete model and control before applying these steps.

RINSE TEMP SENSOR - Service Required - OPENQuestions about Hobart RINSE TEMP SENSOR - Service Required - OPEN
Is RINSE TEMP SENSOR the same as LOW RINSE TEMP?

No. One is a probe failure, the other a measured cool rinse.

Is the rinse sanitizing properly?

The control cannot confirm it, so check with a thermometer or test strip until it is repaired.

Does the message stop the machine?

No. The machine continues to run cycles.