Booking today · Miami, Los Angeles, Houston, New York and San Diego · three-hour arrival windows Independent commercial equipment repair · Every maker on this site Mon–Fri 7:00 AM - 8:00 PM · Sat 8:00 AM - 6:00 PM
(844) 393-0816 Schedule a Visit
Error code · BUNN · Coffee brewers

BUNN Coffee Brewer Message Fill Time Too Long: Check Water Supply

Fill Time Too Long means the tank did not fill in the allowed time. Check that the water supply shut-off is open and the ON/OFF switch is on. If it still shows, service is required.

Medium · inspection needed

Medium: the brewer cannot fill until the supply or solenoid is fixed, but the first checks are easy.

Code
Fill Time Too Long
Maker
BUNN
Equipment
Coffee brewers
Applies to
New Infusion Series (ITB, ITCB, ITCB HV, ICB SH/DV/Twin) display message

What does BUNN Fill Time Too Long mean?

When the brewer starts or the tank needs water, the control opens the inlet solenoid and gives the tank a set time to fill. If the tank has not filled by then, the display shows Fill Time Too Long. The programming manual's Troubleshooting page explains what to check first: that the water supply shut-off to the brewer is open, and that the ON/OFF switch is in the ON position. If both are right, service is required. The causes it lists are water shut off to the brewer, an inlet solenoid failure, a control board failure and the ON/OFF switch being off. The first and last are things anyone can fix in seconds, which is why they come first. The solenoid and the board need a technician. A shut-off valve that was closed during cleaning or plumbing work is a very common reason for this message.

Affected models and control systems

BUNN Infusion Series bean-to-cup brewers: ITB, ITCB and HV models, and the ICB and Twin. Other BUNN brewer lines use a different message list.

Code numbers and their meaning can change between control generations. We match the full model and control before acting on a code.

What you may notice

  • Fill Time Too Long on the display
  • No water sound when the brewer calls for a fill
  • Tank not filling

Possible causes

Listed in BUNN's documentation

  • Water shut off to brewer
  • Inlet solenoid failure
  • Control board failure
  • ON/OFF switch is off

Other likely causes — what usually sits behind Fill Time Too Long on this control. A technician confirms which one it is before any part is replaced.

  • Inlet screen blocked by sediment
  • Water line kinked behind the brewer
  • Low building water pressure at a busy time

Safe checks before calling for service

✓ What an operator can do
  1. Check that the water supply shut-off valve to the brewer is fully open.
  2. Make sure the ON/OFF switch is in the ON position.
  3. Restart the brewer and listen for water filling.
  4. If the message returns, note whether you hear the solenoid click and tell the technician.

How a technician diagnoses Fill Time Too Long

  1. Read the message and confirm the supply pressure.
  2. Check the inlet screen and the water line.
  3. Test the inlet solenoid coil and the voltage to it.
  4. Check the ON/OFF switch and the control board output.
  5. Replace the solenoid or board as needed.
! Leave this to a technician
  • The solenoid is a line-voltage part.
  • Opening the water line can leak onto electrical parts.
  • Telling a failed solenoid from a failed board takes testing.

How Fill Time Too Long differs from similar codes

Fill Time Too Long is a fill alarm. Heating Time Too Long is a heating alarm.

Technical reference

Maker documentation
BUNN owner support
Edition
41581.0003 D 3/20; troubleshooting page stamped 41581.3 120210
Models / control
New Infusion Series (ITB, ITCB, ITCB HV, ICB SH/DV/Twin) display message
Section
Troubleshooting (cont.), p.32
Checked
October 2026

We use the maker's document to read the code and do not reproduce it. Always confirm the complete model and control before applying these steps.

Fill Time Too LongQuestions about BUNN Fill Time Too Long
What should I check first?

The water shut-off and the ON/OFF switch.

Could the supply pressure be low?

Yes, that slows filling.

Will it clear?

Yes, after you open the water or fix the cause.

Book a visit

Need help with BUNN Fill Time Too Long?

A technician confirms the cause on site and gives you the price in writing before any work starts.

☎ Call our office ▤ Schedule a Visit