Booking today · Miami, Los Angeles, Houston, New York and San Diego · three-hour arrival windows Independent commercial equipment repair · Every maker on this site Mon–Fri 7:00 AM - 8:00 PM · Sat 8:00 AM - 6:00 PM
(844) 393-0816 Schedule a Visit
Error code · Henny Penny · Fryers

Henny Penny Electric Fryer Error Code E-6: Temp Sensor Failed

E-6 (A or B) / FRYER TEMP SENSOR FAILED means a failed temperature probe or a bad connection. Have the temperature probe and its connection checked.

Medium · inspection needed

High: the control cannot read the oil temperature, so the fryer stops heating.

Code
E-6 FRYER TEMP SENSOR FAILED
Maker
Henny Penny
Equipment
Fryers
Applies to
Open fryers OFE-321/322 (320 series)

What does Henny Penny E-6 FRYER TEMP SENSOR FAILED mean?

The Computron 1000 control needs the oil temperature probe to know when to heat and when to stop. When the probe or its connection fails, the control shows E-6 / FRYER TEMP SENSOR FAILED, with an A or B after the number. The manual treats the A and B forms together on this control, with a single meaning: a bad probe or a bad connection. It lists one action, have the probe and its connection checked. The older technical manual for the same fryer family shows E-6A and E-6B instead, and the Computron 1000 table combines them. A probe fails when its wire breaks, when its connector corrodes or loosens, or when the sensor itself drifts out of range. The control cannot heat safely without the reading, so frying stops. The cause is usually simple to find with a meter, but the fryer must be cool and isolated first.

Affected models and control systems

Henny Penny OFE-321 and OFE-322 electric open fryers with the Computron 1000 control. The manual we used is a text viewer copy. The display shows E-6 with an A or B, and the manual treats both as the same failure.

Code numbers and their meaning can change between control generations. We match the full model and control before acting on a code.

What you may notice

  • E-6 (A or B) shown with FRYER TEMP SENSOR FAILED
  • Fryer does not heat
  • Temperature not displayed correctly
  • Burner or elements off

Possible causes

Listed in Henny Penny's documentation

  • Failed temperature probe or connection

Other likely causes — what usually sits behind E-6 FRYER TEMP SENSOR FAILED on this control. A technician confirms which one it is before any part is replaced.

  • Probe connector loose at the control
  • Probe wire damaged where it bends
  • Oil or moisture in the probe connector

Safe checks before calling for service

✓ What an operator can do
  1. Turn the fryer off and let it cool before touching anything.
  2. Check that the probe cord is not pinched or hanging in the oil.
  3. Switch the fryer on once and see if the message returns.
  4. Note whether the code shows A or B, then call us.

How a technician diagnoses E-6 FRYER TEMP SENSOR FAILED

  1. Read the code and note whether it shows A or B.
  2. Check the probe connection at the control.
  3. Measure the probe resistance at room temperature.
  4. Inspect the wire for damage.
  5. Replace the probe if the reading is wrong.
! Leave this to a technician
  • The probe is in the oil and the fryer must be cooled and isolated first.
  • Probe resistance needs a meter and the correct values.
  • Wiring behind the panel is on line voltage.

How E-6 FRYER TEMP SENSOR FAILED differs from similar codes

E-6 combines the open and shorted forms; older manuals call them E-6A and E-6B.

Technical reference

Maker documentation
Henny Penny owner support
Edition
Not printed on the page opened (a search snippet showed 'Revised 4-02-09')
Models / control
Open fryers OFE-321/322 (320 series)
Section
Warnings and Error Messages, printed p.1-6
Checked
October 2026

We use the maker's document to read the code and do not reproduce it. Always confirm the complete model and control before applying these steps.

E-6 FRYER TEMP SENSOR FAILEDQuestions about Henny Penny E-6 FRYER TEMP SENSOR FAILED
What do A and B mean?

They are the open and shorted forms in the older manual. The Computron 1000 table lists a single meaning.

Can I keep frying?

No. The control cannot read the oil temperature.

Is the probe always bad?

No. The connection may be the problem.

Book a visit

Need help with Henny Penny E-6 FRYER TEMP SENSOR FAILED?

A technician confirms the cause on site and gives you the price in writing before any work starts.

☎ Call our office ▤ Schedule a Visit