Booking today · Miami, Los Angeles, Houston, New York and San Diego · three-hour arrival windows Independent commercial equipment repair · Every maker on this site Mon–Fri 7:00 AM - 8:00 PM · Sat 8:00 AM - 6:00 PM
(844) 393-0816 Schedule a Visit
Error code · Kold-Draft · Ice machines

Kold-Draft Ice Machine Code 80: Full Rinse Mode Active

Code 80 means the machine is in full-rinse mode because the left jumper on the controller is pulled. It is an optional, less energy-efficient mode, not a malfunction. Replace the jumper and reset the controller to return to normal minimum-rinse mode.

Medium · inspection needed

Low: an informational mode indicator; the machine keeps making ice.

Code
80
Maker
Kold-Draft
Equipment
Ice machines
Applies to
Kold-Draft 60 Series electronic controller (K4B boards, revisions 1.1 to 1.80)

What does Kold-Draft error code 80 mean?

Code 80 is an indicator, not a failure. The controller has a left jumper that selects how much rinsing the machine does. With the jumper in place, the machine runs a minimum rinse, which uses less water and energy. With the jumper pulled, the machine runs a full rinse, and the controller shows 80 (LED 80, full rinse mode). The mode is optional, and some sites choose it on purpose, for example when their water is hard or the product is for a sensitive use. The manual's only cause is the left jumper being pulled. The remedy is to replace the jumper and reset the controller to restore the normal energy-efficient minimum rinse. The manual's troubleshooting table lists Code 80 for Rev 1.3 boards only. If nobody pulled the jumper on purpose, a technician can put it back, but opening the controller is not an operator job.

Affected models and control systems

GT36x, GT56x, GB56x and GB106x Kold-Draft ice makers with the K4B controller. The manual's troubleshooting table shows Code 80 for Rev 1.3 boards.

Code numbers and their meaning can change between control generations. We match the full model and control before acting on a code.

What you may notice

  • LED 80 lit on the controller
  • Longer rinse periods during the cycle
  • Machine otherwise making ice normally

Possible causes

Listed in Kold-Draft's documentation

  • Left jumper pulled on the controller

Other likely causes — what usually sits behind error code 80 on this control. A technician confirms which one it is before any part is replaced.

  • A jumper left off by a technician after board work
  • A site that chose full rinse and forgot to tell the staff

Safe checks before calling for service

✓ What an operator can do
  1. Ask whether anyone chose full-rinse mode on purpose.
  2. Note that the machine is running normally.
  3. Do not open the control box to look for the jumper.
  4. Tell the technician if you want the minimum-rinse mode back.

How a technician diagnoses error code 80

  1. Read the code and confirm Code 80 is the only code shown.
  2. Ask whether full rinse was chosen on purpose.
  3. Open the controller and check the left jumper position.
  4. Replace the jumper if minimum rinse is wanted.
  5. Reset the controller and confirm the LED clears.
! Leave this to a technician
  • The jumper is on the controller board inside a line-voltage control box.
  • Pulling or fitting a jumper with power on risks board damage.
  • Rinse mode affects water and energy use.

How error code 80 differs from similar codes

Code 80 is an information code; codes 10 to 60 report problems.

Technical reference

Maker documentation
Kold-Draft owner support
Edition
Copyright 2015 Kold-Draft International; file named 'new 60 Series Service Manual rev041317' (Kold-Draft says it may not be current)
Models / control
Kold-Draft 60 Series electronic controller (K4B boards, revisions 1.1 to 1.80)
Section
Controller - Fault Codes (revision notes, pp. 21-22) and ERROR-CODE TROUBLESHOOTING (p. 23 onward)
Checked
October 2026

We use the maker's document to read the code and do not reproduce it. Always confirm the complete model and control before applying these steps.

80Questions about Kold-Draft error code 80
Is Code 80 a malfunction?

No. It shows full-rinse mode.

Why would anyone use full rinse?

It is optional; some sites prefer it despite the higher energy use.

How do I turn it off?

Replace the jumper and reset the controller.

Book a visit

Need help with Kold-Draft error code 80?

A technician confirms the cause on site and gives you the price in writing before any work starts.

☎ Call our office ▤ Schedule a Visit