Kold-Draft Ice Machine Code 90: Bin Full

Code 90 means the ice bin is full and the cold bin probe is shutting the ice maker down after the current harvest. This is a normal condition, not a malfunction. If it shows with an empty bin, a technician should check the bin probe, its wiring and the controller board.

Medium · inspection needed

Low: a normal bin-full stop; the machine restarts when ice is used.

Code
90
Maker
Kold-Draft
Equipment
Ice machines
Applies to
Kold-Draft 60 Series electronic controller (K4B boards, revisions 1.1 to 1.80)

What does Kold-Draft error code 90 mean?

Code 90 is a normal stop. The ice maker has a bin probe that senses when ice has built up to its level. When the probe is cold because ice is touching it, the controller finishes the current harvest and then stops, showing 90 (LED 90, bin full). The machine restarts on its own once ice is used and the probe warms. The manual lists the cold bin probe as the cause when the bin is full, and says no action is needed. The case to look at is Code 90 with a bin that is not full. Then the manual points to a defective bin probe, its wiring or the controller board. A probe out of position is also a possible reason for it to read cold, though that is a likely cause, not a documented one. The manual's troubleshooting table lists Code 90 for Rev 1.3 boards only.

Affected models and control systems

K4B-equipped Kold-Draft cube makers (GT36x, GT56x, GB56x, GB106x). The troubleshooting table lists Code 90 under Rev 1.3 only.

Code numbers and their meaning can change between control generations. We match the full model and control before acting on a code.

What you may notice

  • LED 90 lit on the controller
  • Machine idle with a full bin
  • Machine idle with a bin that is only partly full

Possible causes

Listed in Kold-Draft's documentation

  • Bin probe cold because the bin is full
  • Defective bin probe, wiring or controller if the bin is not full

Other likely causes — what usually sits behind error code 90 on this control. A technician confirms which one it is before any part is replaced.

  • Ice melt or frost bridging the bin probe tip so it reads cold
  • A bin probe bent into the ice stream

Safe checks before calling for service

✓ What an operator can do
  1. Look in the bin to see whether ice is at the probe's level.
  2. If the bin is full, use some ice and see whether the machine restarts.
  3. If the bin is not full, check that nothing is touching the probe, without bending it.
  4. If Code 90 stays with a low bin, tell the technician how much ice was in the bin.

How a technician diagnoses error code 90

  1. Read the code and check how much ice is in the bin.
  2. Remove ice from around the probe and see whether the machine restarts.
  3. Check the bin probe position and wiring.
  4. Measure the probe signal at the controller.
  5. Replace the probe or the controller board when the signal stays cold.
! Leave this to a technician
  • The probe wires lead into the control box.
  • Telling a cold probe from a bad signal needs a meter.
  • Bending the probe changes where the machine stops.

How error code 90 differs from similar codes

Code 90 is a normal stop condition; codes 10 to 60 report problems.

Technical reference

Maker documentation
Kold-Draft owner support
Edition
Copyright 2015 Kold-Draft International; file named 'new 60 Series Service Manual rev041317' (Kold-Draft says it may not be current)
Models / control
Kold-Draft 60 Series electronic controller (K4B boards, revisions 1.1 to 1.80)
Section
Controller - Fault Codes (revision notes, pp. 21-22) and ERROR-CODE TROUBLESHOOTING (p. 23 onward)
Checked
October 2026

We use the maker's document to read the code and do not reproduce it. Always confirm the complete model and control before applying these steps.

90Questions about Kold-Draft error code 90
Is Code 90 a problem?

Not when the bin is full.

When does it restart?

When enough ice is removed that the probe warms.

What if the bin is empty?

Then the probe, wiring or controller needs a check.