Model series · Turbo Air · Prep tables

Turbo Air PST Pizza Prep Tables

Current line. 103 model numbers in this series.

01Model numbers

Model numbers in this series

Find yours on the data plate. Letters after the base number usually mark the voltage, finish or door and do not change the repair.

  • PST-28-12-D2-N
  • PST-28-12-FB-N
  • PST-28-12-N
  • PST-28-D2-FB-N
  • PST-28-D2-N
  • PST-28-D2-N-1
  • PST-28-FB-N
  • PST-28-G-N
  • PST-28-N
  • PST-28-N-GL
  • PST-36-15-N-SL
  • PST-36-N
  • PST-48-08S-N
  • PST-48-08S-N-CL
  • PST-48-08S-N-FCL
  • PST-48-08S-N-FL
  • PST-48-12M-N
  • PST-48-12M-N-CL
  • PST-48-12M-N-FCL
  • PST-48-12M-N-FL
  • PST-48-18-D2L-N-GL-1
  • PST-48-18-D2R
  • PST-48-18-D2R-FB-N-1
  • PST-48-18-D2R-N
  • PST-48-18-D4-FB-N
  • PST-48-18-D4-N
  • PST-48-18-FB-N
  • PST-48-18-FB-N-FL
  • PST-48-18-N
  • PST-48-18-N-DS
  • PST-48-18-N-FL
  • PST-48-18-N-GL
  • PST-48-18-N-GL-1
  • PST-48-D2R
  • PST-48-D2R-FB-N
  • PST-48-D2R-N
  • PST-48-D2R-N-1
  • PST-48-D4-FB-N
  • PST-48-D4-N
  • PST-48-D4-N-1
  • PST-48-FB-N
  • PST-48-G-N
  • PST-48-G-N-1
  • PST-48-N
  • PST-48-N-GL
  • PST-60-08S-N
  • PST-60-08S-N-CL
  • PST-60-08S-N-FCL
  • PST-60-08S-N-FL
  • PST-60-12M-N
  • PST-60-12M-N-CL
  • PST-60-12M-N-FCL
  • PST-60-12M-N-FL
  • PST-60-24-D2L-N
  • PST-60-24-D2R
  • PST-60-24-D2R-FB-N
  • PST-60-24-D4-FB-N
  • PST-60-24-D4-N
  • PST-60-24-D4-N-FL
  • PST-60-24-D4-N-GL
  • PST-60-24-D4-N-GL-1
  • PST-60-24-FB-N
  • PST-60-24-FB-N-FL
  • PST-60-24-N
  • PST-60-24-N-DS
  • PST-60-24-N-FL
  • PST-60-24-N-GL
  • PST-60-24-N-GL-1
  • PST-60-D2R
  • PST-60-D2R-FB-N
  • PST-60-D2R-N
  • PST-60-D2R-N-1
  • PST-60-FB-N
  • PST-60-G-N
  • PST-60-G-N-1
  • PST-60-N
  • PST-60-N-GL
  • PST-72-30-D2R-N
  • PST-72-30-D4-N
  • PST-72-30-D4-N-GL
  • PST-72-30-D4-N-GL-1
  • PST-72-30-D4-N-SL
  • PST-72-30-D4L-N
  • PST-72-30-D4R
  • PST-72-30-D6-N
  • PST-72-30-D6-N-SL
  • PST-72-30-D6-N-SL-1
  • PST-72-30-FB-N
  • PST-72-30-N
  • PST-72-30-N-CL
  • PST-72-30-N-CL-1
  • PST-72-30-N-DS
  • PST-72-30-N-DS-1
  • PST-72-30-N-FL
  • PST-72-30-N-GL
  • PST-72-30-N-GL-1
  • PST-72-D6-FB-N
  • PST-72-D6-N
  • PST-72-FB-N
  • PST-72-G-N
  • PST-72-G-N-2
  • PST-72-N
  • PST-72-N-GL

Repairs this series usually needs

  1. Warm rail from flour in the condenser
  2. Key lock or alarm light on the controller
  3. Drain hose out of the drain pan
  4. Lid and drawer gasket wear
  5. Evaporator frost

The PST is Turbo Air’s pizza prep table, and the list holds 103 numbers, such as PST-28-12-N, PST-28-12-D2-N and PST-48-18-N. The controller shows lights for the compressor, defrost, evaporator fan, key lock, door open and alarm, which gives us a quick view of what the table was doing.

The compressor turns on at 38 F return air and off at 34 F, so a table that cycles in that range is normal. Flour and cheese dust clog the condenser, and the drain hose can slip out of the pan and leave water on the floor. We check both, and the self-cleaning condenser models still need a nitrogen blow-out once or twice a year. We confirm the plate number first so gaskets and drawer parts are on the truck.

About this series

  • Refrigerated pizza prep tables
  • Controller with lights for compressor, defrost, evaporator fan, key lock, door open and alarm
  • Models such as PST-28-12-N and PST-48-18-N
  • 103 model numbers
FAQTurbo Air PST Pizza Prep Tables questions
What temperatures does a PST hold?

The compressor turns on at 38 F return air and off at 34 F. A table that cycles around those values is normal. Watch the compressor light.

Why is there water under my PST?

The drain hose may have slipped out of the drain pan. We put it back and check the pan and the line. Check that the hose points into the pan.

What do the controller lights tell you?

They show compressor, defrost, fan, key lock, door open and alarm states. They help us see what the table was doing when the problem started.