Henny Penny OFG-391 Fryer Error Code E-10: High Limit Tripped

E-10 means the high limit has tripped. Manually push up on the red reset button. If it will not reset, the high limit must be replaced, so call the Service Department.

Medium · inspection needed

High: the oil exceeded a safety limit, so the fryer must not be used until the cause is found.

Code
E-10
Maker
Henny Penny
Equipment
Fryers
Applies to
Open fryer OFG-391

What does Henny Penny error code E-10 mean?

A high limit is a safety thermostat that cuts the heat if the oil goes above a safe temperature. On the Henny Penny OFG-391 open gas fryer it is a separate device from the probe that controls normal frying. If the oil gets too hot, the high limit opens and the controller shows E-10. The manual's action is to manually push up on the red reset button, and if the limit will not reset, it must be replaced, so call the Service Department. A tripped limit means oil temperature went beyond what the normal control allows, or the limit has weakened with age. Resetting restores the heat but not the cause. If E-10 comes back soon after a reset, the temperature control or the limit itself needs attention. Always let the oil cool before touching the red button.

Affected models and control systems

Henny Penny OFG-391 open gas fryer. The manual copy we used is a text viewer copy of the Henny Penny manual. The code has a red reset button.

Code numbers and their meaning can change between control generations. We match the full model and control before acting on a code.

What you may notice

  • E-10 on the controller
  • Fryer stops heating
  • Oil was hotter than normal
  • Red reset button popped out

Possible causes

Listed in Henny Penny's documentation

  • High limit tripped

Other likely causes — what usually sits behind error code E-10 on this control. A technician confirms which one it is before any part is replaced.

  • Temperature probe or control reading low so oil overheated
  • Vat refilled too little after filtering so the oil sits below the high limit sensing point
  • High limit weakened and tripping early

Safe checks before calling for service

✓ What an operator can do
  1. Turn the fryer off and let the oil cool completely.
  2. Push up on the red reset button as the manual says.
  3. Restart and watch the oil temperature.
  4. If it trips again or will not reset, stop and call us.

How a technician diagnoses error code E-10

  1. Read the code and confirm E-10.
  2. Let the oil cool and reset the high limit.
  3. Compare the temperature probe reading with a thermometer.
  4. Check the oil level and the heating control.
  5. Replace the high limit if it will not reset.
! Leave this to a technician
  • Hot oil is a burn and fire hazard, so repeat overheating needs a proper diagnosis.
  • The limit and control circuit carry gas-fryer controls and line voltage.
  • A limit that will not reset must be replaced, not bypassed.

How error code E-10 differs from similar codes

E-10 is the high limit trip; E-6A and E-6B are probe alarms.

Technical reference

Maker documentation
Henny Penny owner support
Edition
Not printed on the pages opened
Models / control
Open fryer OFG-391
Section
Error Codes, printed p.1-10 (page 305)
Checked
October 2026

We use the maker's document to read the code and do not reproduce it. Always confirm the complete model and control before applying these steps.

E-10Questions about Henny Penny error code E-10
Is it safe to reset the red button?

Only after the oil has cooled, and only once or twice.

Why did it trip?

The oil got hotter than the high limit allows, or the limit is weak.

What if it will not reset?

The manual says the high limit must be replaced.

Book a visit

Need help with Henny Penny error code E-10?

A technician confirms the cause on site and gives you the price in writing before any work starts.

☎ Call our office ▤ Schedule a Visit