Error code · Hobart · Mixers

Hobart Legacy+ Mixer Error Er3: CPU Error in the Motor Drive

Er3 is a CPU error on Hobart Legacy+ HL800 and HL1400 mixers, which the owner's manual ties to a malfunction in the motor drive. Cut power, wait for the display to go dark, then restore power and start a normal batch with the guard closed. Write down when Er3 appears; if it returns, stop and call us.

Medium · inspection needed

Medium: the mixer stops until power is cycled, and a repeating CPU error points to the drive.

Code
Er3
Maker
Hobart
Equipment
Mixers
Applies to
Legacy+ HL800 / HL1400 motor drive + SmartTimer display

What does Hobart error code Er3 mean?

The motor drive contains a processor that runs its own program. If that processor stops working normally, the drive reports a CPU error, and the SmartTimer display shows Er3. The mixer will not run until power is cycled and the cause is corrected. Because a power event just before the code can upset the processor, one Er3 followed by normal operation may need no repair at all. An Er3 that comes back points to the drive itself. Supply voltage and connection quality at the drive are checked next, since a poor connection can disturb the processor in the same way. A drive that resets itself after a code may be hiding a failing board, which is why the occurrence log you keep is useful: how often the code appears, what the mixer was doing, and whether any lights flickered. The display gives no detail beyond the CPU error. The text on the display is Er3, and it applies to the HL800 and HL1400.

Affected models and control systems

Hobart Legacy+ HL800 and HL1400 mixers with the motor drive and SmartTimer display. Other generations of Hobart mixers use different codes.

Code numbers and their meaning can change between control generations. We match the full model and control before acting on a code.

What you may notice

  • Er3 on the SmartTimer display
  • Mixer stops and will not restart
  • Code returning at random points in a batch

Possible causes

Listed in Hobart's documentation

  • Power event just before the code
  • Supply voltage and connection quality at the drive
  • Drive board, if the code repeats

Other likely causes — what usually sits behind error code Er3 on this control. A technician confirms which one it is before any part is replaced.

  • Electrical noise from a nearby large motor that upsets the processor
  • A drive that overheated in a closed, warm base and reset itself

Safe checks before calling for service

✓ What an operator can do
  1. Cut power to the mixer, wait for the display to go dark, then restore power.
  2. Start a normal batch with the bowl guard closed.
  3. Write down when Er3 appears and what the mixer was doing.
  4. If it returns, stop and call us.
  5. Tell us whether the mixer was loaded heavily and how long it had been running.

How a technician diagnoses error code Er3

  1. Read Er3 and review the notes on when it appears.
  2. Check the supply voltage and connections at the disconnect and drive input.
  3. Look for evidence of heat or contamination around the drive.
  4. Log whether the code correlates with load or start-up.
  5. Cycle power and run a batch to see if Er3 repeats.
  6. Replace the drive if Er3 returns with a verified supply.
! Leave this to a technician
  • The drive is wired to 208 to 240 V input and keeps stored charge after switch-off.
  • The display gives no detail beyond the CPU error, so we measure the supply and test the drive before any part is ordered.
  • A drive that resets itself can hide a failing board, which only a repeat test under load shows.

Technical reference

Document
Large Capacity Mixers Customer Maintenance Manual F48065 (10-22), Diagnostic Error Codes
Maker documentation
Hobart owner support
Edition
F48065
Models / control
Legacy+ HL800 / HL1400 motor drive + SmartTimer display
Section
Diagnostic Error Codes HL800 & HL1400, PDF pp. 9-11
Checked
October 2026

We use the maker's document to read the code and do not reproduce it. Always confirm the complete model and control before applying these steps.

Er3Questions about Hobart error code Er3
Is Er3 always a bad drive?

No. One occurrence after a power event may clear, but repeats point to the drive.

What should I write down?

The time, what the mixer was doing and any power flicker.

Is it the same as Er1?

No. Er1 is a memory error; Er3 is the processor itself.

Book a visit