BUNN Coffee Brewer Message Temp Sensor Out Of Range: Check Connections

Temp Sensor Out Of Range, Check For Bad Connections means the temperature probe wire is broken or not making contact, an open circuit. Check the wire and connection of both the black and white probe wires.

Medium · inspection needed

High: the control cannot read the tank temperature, so heating is not safe.

Code
Temp Sensor Out Of Range, Check For Bad Connections
Maker
BUNN
Equipment
Coffee brewers
Applies to
New Infusion Series (ITB, ITCB, ITCB HV, ICB SH/DV/Twin) display message

What does BUNN Temp Sensor Out Of Range mean?

The brewer reads the tank temperature through a probe with two wires, one black and one white. The control expects a resistance within a normal range. If a wire is broken or has pulled out of its connector, the circuit is open and the reading is out of range. The control then displays Temp Sensor Out Of Range, Check For Bad Connections. The programming manual's Troubleshooting page gives the action: check the wire and connection of both the black and white probe wires. The only cause listed is that the probe wires are broken or not making connection. This message differs from the one that says Check Wire For Shorts. That one means the wires are touching the housing or each other. An open circuit reads as very high resistance, and a short reads as very low, and the control tells them apart.

Affected models and control systems

BUNN Infusion Series bean-to-cup brewers: ITB, ITCB and HV models, and the ICB and Twin. Other BUNN brewer lines use a different message list.

Code numbers and their meaning can change between control generations. We match the full model and control before acting on a code.

What you may notice

  • Temp Sensor Out Of Range, Check For Bad Connections on the display
  • Brewer will not heat or brew
  • Temperature reading missing

Possible causes

Listed in BUNN's documentation

  • Probe wire(s) broken or not making connection

Other likely causes — what usually sits behind Temp Sensor Out Of Range on this control. A technician confirms which one it is before any part is replaced.

  • Probe connector loosened during cleaning
  • Wire stretched when the brewer was moved
  • Corrosion at the probe terminals

Safe checks before calling for service

✓ What an operator can do
  1. Switch the brewer off and unplug it.
  2. Do not open the brewer or touch the probe wires.
  3. Switch it on again after a minute to see whether the message returns.
  4. If it returns, note it and tell the technician.

How a technician diagnoses Temp Sensor Out Of Range

  1. Read the message and confirm it is the open circuit version.
  2. Inspect both the black and white probe wires and the connections.
  3. Measure the probe resistance and continuity.
  4. Reseat or repair the connection, or replace the probe.
  5. Check the temperature reading after the repair.
! Leave this to a technician
  • The probe circuit connects to the live control board.
  • Access to the probe means opening the brewer and handling hot parts.
  • A bad reading can lead to overheating if misread.

How Temp Sensor Out Of Range differs from similar codes

This is the open circuit version. The Check Wire For Shorts message is the short circuit version.

Technical reference

Maker documentation
BUNN owner support
Edition
41581.0003 D 3/20; troubleshooting page stamped 41581.3 120210
Models / control
New Infusion Series (ITB, ITCB, ITCB HV, ICB SH/DV/Twin) display message
Section
Troubleshooting (cont.), p.32
Checked
October 2026

We use the maker's document to read the code and do not reproduce it. Always confirm the complete model and control before applying these steps.

Temp Sensor Out Of RangeQuestions about BUNN Temp Sensor Out Of Range
What does open mean?

The probe wire has no connection, like a cut wire.

Which wires should I check?

The manual says both the black and white probe wires.

Is it the same as the shorts message?

No. That message means the wires are shorted.