La Marzocco Espresso Machine Error Code: Steam Boiler Is Not Heating

Steam Boiler Is Not Heating means the steam boiler did not reach the minimum temperature within the programmed time interval. The manual refers to the Heating Timeout parameter. A service technician should check the steam heating circuit.

Medium · inspection needed

High: the steam boiler cannot reach temperature, so steam is unavailable.

Code
Steam Boiler Is Not Heating
Maker
La Marzocco
Equipment
Espresso machines
Applies to
Linea PB and Strada AV

What does La Marzocco Steam Boiler Is Not Heating mean?

After start-up, the CPU gives the steam boiler a set time to reach its minimum temperature. That limit is the Heating Timeout parameter. If the boiler is still below minimum when the time is up, the CPU shows Steam Boiler Is Not Heating. The reason can be a burned-out element, a relay that does not close, a safety device that has opened, the electrical supply, or a timeout that is too short for the installation. A steam boiler that is not full also warms slowly, so an autofill problem can look similar. The message is separate from the probe message, which says the probe is not detected, and from the overheated message. From the counter, the steam wand simply produces little or no steam, and the pressure stays low long after the machine was switched on. Heating Timeout is the parameter the manual points to, and it sets how long the CPU waits before declaring the failure.

Affected models and control systems

La Marzocco Linea PB (display software, Operating Manual V3.2) and Strada AV (MAN.16.1.01 V1.0). Boiler names and numbers on the display follow the machine's group and boiler count.

Code numbers and their meaning can change between control generations. We match the full model and control before acting on a code.

What you may notice

  • Steam Boiler Is Not Heating on the display
  • No steam from the wand
  • Pressure stays low
  • Message returns after switching on

Possible causes

Likely causes — what usually sits behind Steam Boiler Is Not Heating on this control. A technician confirms which one it is before any part is replaced.

  • Steam boiler heating element burned out
  • Heater relay or safety thermostat open
  • Missing phase or low voltage
  • Heating Timeout shorter than the boiler needs

Safe checks before calling for service

✓ What an operator can do
  1. Check that the machine's breaker and wall disconnect are on.
  2. Switch off and on once.
  3. Do not keep restarting if it does not heat.
  4. Keep clear of the boiler area.
  5. Note how long the machine ran and whether the coffee boiler heated.

How a technician diagnoses Steam Boiler Is Not Heating

  1. Read the message and the Heating Timeout parameter.
  2. Measure supply voltage on every phase under load.
  3. Check the element for continuity and leakage to ground with power off.
  4. Test the heater relay and safety thermostat.
  5. Confirm the steam boiler is full and the probe reads correctly, then replace the failed part.
! Leave this to a technician
  • Heating circuits draw high current at line voltage.
  • The steam boiler holds hot pressurized water.
  • A meter is needed to separate element, relay and supply.

How Steam Boiler Is Not Heating differs from similar codes

This message is about the steam boiler failing to reach temperature. The coffee boiler has a similar message with its own number.

Technical reference

Maker documentation
La Marzocco owner support
Edition
V3.2 - 12/2015 (La Marzocco S.r.l.)
Models / control
Linea PB and Strada AV
Section
Troubleshooting, printed pp. 104-105 (PDF pp. 104-105)
Checked
October 2026

We use the maker's document to read the code and do not reproduce it. Always confirm the complete model and control before applying these steps.

Steam Boiler Is Not HeatingQuestions about La Marzocco Steam Boiler Is Not Heating
What is Heating Timeout?

The parameter setting the time the boiler may take to reach its minimum temperature.

Could low water cause it?

A short boiler can be slow to warm, so autofill is checked.

Is it the probe?

A probe problem gives a different message.