Model numbers in this series
Find yours on the data plate. Letters after the base number usually mark the voltage, finish or door and do not change the repair.
- WTF20HC
- WTF20HC-FIP
- WTF20HC-FLT
- WTF24AHC
- WTF24AHC-25
- WTF24AHC-FIP
- WTF24AHC-FLT
- WTF27AHC
- WTF27AHC-FIP
- WTF27AHC-FLT
- WTF27HC
- WTF27HC-25
- WTF27HC-FIP
- WTF27HC-FLT
- WTF32AHC
- WTF32AHC-25
- WTF32AHC-FIP
- WTF32AHC-FLT
- WTF36AHC
- WTF36AHC-25
- WTF36AHC-FIP
- WTF36AHC-FLT
- WTF48AHC
- WTF48AHC-25
- WTF48AHC-FIP
- WTF48AHC-FLT
- WTF60AHC
- WTF60AHC-25
- WTF60AHC-FIP
- WTF60AHC-FLT
- WTF67AHC
- WTFD27AHC-2
- WTFD27AHC-2-FIP
- WTFD27AHC-2-FLT
- WTFD32AHC-2
- WTFD32AHC-2-FIP
- WTFD32AHC-2-FLT
- WTFD36AHC-2
- WTFD36AHC-2-FIP
- WTFD36AHC-2-FLT
- WTFD48AHC-2
- WTFD48AHC-2-FIP
- WTFD48AHC-2-FLT
- WTFD48AHC-4
- WTFD48AHC-4-FIP
- WTFD48AHC-4-FLT
- WTFD60AHC-2
- WTFD60AHC-2-FIP
- WTFD60AHC-2-FLT
- WTFD60AHC-4
- WTFD60AHC-4-FIP
- WTFD60AHC-4-FLT
Repairs this series usually needs
- Frost on the coil
- Warm freezer from a dirty condenser
- Door and drawer gasket wear
- Hi or Lo alarms
- Sensor codes
The WTF is the Beverage-Air worktop freezer, with 52 numbers such as WTF20HC, WTF20HC-FIP, WTF20HC-FLT and WTF48AHC. It is a low freezer with a work surface on top, used beside cooking stations.
Heat and flour from the line reach the condenser through the grille, so we start there. We then check every gasket, since a long cabinet has several, then the defrost and the fans. The Lo alarm on a WTF48AHC points to the Danfoss control, and we compare the display with a thermometer.
Suffixes such as -FIP and -FLT mark variants, so please read the full number. A long freezer has several doors, and we check each one on its own before we decide the repair is finished. We confirm the control type first.
About this series
- Worktop freezers
- Models such as WTF20HC and WTF48AHC
- Eliwell or Danfoss electronic control, model by model
- 52 model numbers
Other Beverage-Air reach-in freezers series
CT12-12HCCT12-12HC-1HGCT12-12HC-1HSCT12-12HC-1HSDCT1HCCT1HC-1GCT1HC-1HGCT1HC-1HS+6 more→Beverage-Air FB Bottom-Mount FreezersCurrent lineFB12HC-1SFB19HC-1GFB19HC-1SFB23HC-1GFB23HC-1SFB27HC-1GFB27HC-1SFB35HC-1G+7 more→Beverage-Air HF Top-Mount FreezersCurrent lineHF1HC-1GHF1HC-1HGHF1HC-1HSHF1HC-1SHF1WHC-1SHF2HC-1GHF2HC-1HGHF2HC-1HS+5 more→Beverage-Air Horizon HBF Bottom-Mount FreezersCurrent lineHBF12HC-1HBF12HC-1-GHBF19HC-1HBF19HC-1-GHBF23HC-1HBF23HC-1-GHBF23HC-1-HGHBF23HC-1-HS+14 more→Beverage-Air PF, PFI, PFD and PFT Pass-Thru FreezersCurrent linePF1HC-1AHSPF1HC-1ASPF1HC-1BGPF1HC-1BHGPF2HC-1AHSPF2HC-1ASPF2HC-1BGPF2HC-1BHG+4 more→Beverage-Air SMF and STF School Milk FreezersCurrent lineSMF34HCSMF49HCSMF58HC→Beverage-Air UCF Undercounter FreezersCurrent lineUCF20HCUCF20HC-25-15UCF24AHCUCF24HCUCF27AHCUCF27HCUCF32AHCUCF36AHC+10 more→Beverage-Air WTFCS 36 Inch Worktop FreezersCurrent lineWTFCS36HCWTFCS36HC-48→What do suffixes like -FLT mean?
They mark variants with different options. We use the full number to match gaskets and parts, so please read us everything printed on the plate.
Why is my worktop freezer icing up?
Humid air through a worn gasket is the usual cause. We replace the gasket and check the defrost. A tired door seal on a long cabinet is the usual cause.
Does the work surface get cold?
The top stays near room temperature. Any condensation on it suggests an issue we should look at, such as a leaking seal or a failed door heater.
Book repair for your Beverage-Air WTF Worktop Freezers