Scotsman Prodigy Eclipse EH Remote Low-Side Cubers
Current and older. 7 model numbers in this series.
Model numbers in this series
Find yours on the data plate. Letters after the base number usually mark the voltage, finish or door and do not change the repair.
- EH130
- EH222
- EH330
- EH430
- ECC1200
- ECC1410
- ECC1800
Repairs this series usually needs
- Max freeze and max harvest retries and shutdowns
- Slow water fill
- High discharge temperature
- Sump and discharge sensor failures
- Short freeze and thin ice
The Prodigy Eclipse EH machines are remote low-side cubers: the ice head makes ice in the kitchen and the ECC condensing unit sits outside. Models include the EH130, EH222, EH330 and EH430 with the ECC1200, ECC1410 and ECC1800 condensing units.
The controller uses the same code list as the ELITE: 1 for max freeze, 2 for max harvest, 3 for slow water fill, 4 for high discharge temperature, 5 and 7 for sensors, and 8 for short freeze. The controller also limits freezes to 45 minutes and harvests to 3.5 minutes, and it restarts after a wait of 50 minutes.
Because the condensing unit lives outside sun and humidity, we look at it early, along with water supply and scale.
About this series
- Remote low-side cubers paired with an ECC condensing unit
- Models EH130, EH222, EH330 and EH430
- Condensing units ECC1200, ECC1410 and ECC1800
- Maximum freeze 45 minutes, minimum freeze 6 minutes and maximum harvest 3.5 minutes
Scotsman ice machines codes
Other Scotsman ice machines series
CME250CME256CME306CME456CME456RCME500CME500RCME506+29 more→Scotsman CU Undercounter, HID Dispenser and Older Ice MachinesCurrent and olderCU0415CU0515CU0715CU0920CU50CU3030CU0415XCU0715X+28 more→Scotsman Prodigy and Prodigy Plus Modular CubersCurrent and olderC0322C0522C0722C0330C0530C0630C0830C1030+7 more→Scotsman Prodigy ELITE Modular Ice MachinesCurrent lineMC222LMC0322MC0522MC0722MC0330MC0530MC0630MC0830+16 more→Scotsman Prodigy Plus Flake and Nugget Ice MachinesCurrent lineFS0522FS0822FS1222FS1522NH0422NS0422NH0622NS0622+16 more→What is a low-side cuber?
The ice head holds the evaporator side of the refrigeration system, and the condensing unit holds the compressor and condenser. Refrigerant lines connect the two.
Do the codes match the ELITE?
Yes. The EH list uses the same wording as the ELITE list for codes 1, 2, 3, 4, 5, 7 and 8. We still confirm the model first.
Where is the condensing unit?
It is usually outdoors or on a roof. Tell us where yours is when you book so we can plan access and bring the right gear.