Eversys Coffee Machine Error Code S-007: Reinsert Grounds Drawer
S-007 means the grounds drawer was out for too long, and after it is reinserted the control will ask whether it was emptied. Put the drawer back and answer YES or NO honestly.
Low: a prompt; the machine continues once the drawer is back and the question is answered.
- Code
- S-007
- Maker
- Eversys
- Equipment
- Super-automatic coffee
- Applies to
- Eversys Cameo range (Cameo/Core, Classic, ST, in-box), e'Support article
What does Eversys error code S-007 mean?
The Cameo times how long the grounds drawer stays out. If it is out longer than the control allows, it assumes the drawer may have been emptied and shows "Please insert the grounds drawer." as S-007. The maker's table explains that the drawer out time has elapsed, and that when the drawer is inserted now, a message box appears asking whether the grounds drawer has been emptied, with YES or NO. The answer matters because the control uses it to reset its count of used grounds. Answering YES when the drawer was not emptied means the machine will not know it is full. The table gives no failure cause, so this is a normal prompt. Reinserting the drawer promptly after emptying avoids this prompt in the first place.
Affected models and control systems
Eversys Cameo range (Cameo/Core, Classic, ST and in-box versions), as covered by the maker's e'Support table of S-number stop messages.
Code numbers and their meaning can change between control generations. We match the full model and control before acting on a code.
What you may notice
- S-007 after the drawer was pulled out
- A YES or NO question appears after reinserting
- Drinks are held until the drawer is back in
Possible causes
Likely causes — what usually sits behind error code S-007 on this control. A technician confirms which one it is before any part is replaced.
- Grounds drawer out longer than the allowed time
- The drawer was taken out for cleaning and left out through a rush
- The drawer was put back crooked and not detected
- A drawer switch that does not register the drawer when it is reinserted
Safe checks before calling for service
- Slide the grounds drawer fully back in.
- When the message box asks, answer YES only if you emptied it.
- If you did not empty it, answer NO and empty it.
- If S-007 repeats with the drawer seated, report it.
How a technician diagnoses error code S-007
- Confirm the drawer is seated and the switch registers it.
- Check the answer was recorded and the count reset.
- Test the drawer switch input.
- Replace the switch if it reads wrongly.
- The drawer switch is read at the control board with the machine powered.
- A wrong grounds count can only be corrected from the machine's settings.
How error code S-007 differs from similar codes
S-008 uses the same wording but is the plain request when the drawer is simply absent.
Technical reference
- Document
- Operator stop messages for Cameo (S-XXX)
- Models / control
- Eversys Cameo range (Cameo/Core, Classic, ST, in-box), e'Support article
- Section
- Web page table of S-numbers, Infos messages and Explanations / Remedies (no page numbers)
- Checked
- October 2026
We use the maker's document to read the code and do not reproduce it. Always confirm the complete model and control before applying these steps.
Related Eversys super-automatic coffee error codes
What happens if I say YES but did not empty it?
The control resets its count and may let the drawer overfill later.
Why does it ask?
Because the drawer was out longer than the allowed time.
Is it the same as S-008?
The text is the same. S-007 follows the time-out and leads to the YES or NO question.
Need help with Eversys error code S-007?