Booking today · Miami, Los Angeles, Houston, New York and San Diego · three-hour arrival windows Independent commercial equipment repair · Every maker on this site Mon–Fri 7:00 AM - 8:00 PM · Sat 8:00 AM - 6:00 PM
(844) 393-0816 Schedule a Visit
Brand · Super-automatic coffee

Eversys Automatic Coffee Machine Repair

We repair Eversys super-automatic coffee machines, including the Cameo, the Enigma and Shotmaster e'2 and e'4, and the E'Line, in Miami, Los Angeles, Houston, New York and San Diego. Give us the E, W or S message and we plan the parts.

1kind of equipment
2model series listed
126error codes explained
30 daysworkmanship warranty
01What goes wrong

Common Eversys problems we fix

In plain words, the way kitchen and laundry staff describe them when they call.

01

E message with machine in standby

02

W-004 water flow too low

03

Grinder blocked W-068 or W-069

04

Rinse or cleaning necessary S-014

05

Steam boiler fill timeout

06

Milk system cleaning message

Eversys Lines We Repair

Eversys machines are super-automatic and busy, so downtime hurts. We repair the Cameo and Cameo C, the Enigma and Shotmaster machines, including the e’2 and e’4, which have left and right coffee boilers, and the E’Line series. The Cameo uses cleaning balls, the Everclean milk cleaning system and a steam boiler.

The messages come in three families. E messages are errors that need attention, W messages are warnings, and S messages are service prompts. E-011 to E-014 and E-023 say that a unit, such as the hydraulic, milk, brewing, grinder or water pump unit, is not connected. E-050 is a communication error between the two processors, and E-099 is a lost connection between the display and the processor. E-021 says the grinder motor ran endlessly and power was cut. E-102, E-103 and E-104 involve the steam boiler fill and heating timeouts.

Warnings, Cleaning and First Steps

W-004 means water flow is too low, and we look at the filter and at coffee ground too fine. W-068, W-069, W-080 and W-081 say a grinder is blocked. W-014 is a water filter replacement, and S-014 and S-017 ask for rinsing or cleaning. W-037 and S-028 tell us the milk system was cleaned without detergent, which is why the maker calls for Everclean detergent, one pump of 25 ml, in the milk cleaning cycle.

When a machine goes into standby because a boiler overheated, as E-017 and E-094 do, we find out why before we bring it back. For communication errors, the manual’s first step is to switch the machine off, wait ten seconds and switch it on, and you can do that before you call. Scale in boilers is common with hard water, so we check the water treatment too. The price is written down before we begin, and the work has a 30-day warranty.

→Error codes

Eversys codes and alarms

What the display or the blinking light means, what is safe to check, and when to stop and call us.

E-010Eversys Automatic Coffee Machine Error Code E-010: CPU SoftwareE-011Eversys Automatic Coffee Machine Error Code E-011: Hydraulic UnitE-012Eversys Automatic Coffee Machine Error Code E-012: Milk UnitE-013Eversys Automatic Coffee Machine Error Code E-013: Brewing UnitE-014Eversys Automatic Coffee Machine Error Code E-014: Grinder UnitE-021Eversys Automatic Coffee Machine Error Code E-021: Grinder MotorE-023Eversys Automatic Coffee Machine Error Code E-023: Water Pump UnitE-094Eversys Automatic Coffee Machine Error Code E-094: Boiler OverheatingE-097Eversys Automatic Coffee Machine Error Code E-097: Set Machine TypeE-102Eversys Automatic Coffee Machine Error Code E-102: Steam Boiler EmptyE-017Eversys Cameo Coffee Machine Error Code E-017: Boiler OverheatingE-050Eversys Coffee Machine Error Code E-050: Inter-CPU LinkE-098Eversys Coffee Machine Error Code E-098: Software UpdateE-099Eversys Coffee Machine Error Code E-099: Display LinkE-103Eversys Coffee Machine Error Code E-103: Steam Fill TimeoutE-104Eversys Coffee Machine Error Code E-104: Steam Heating TimeoutE-105Eversys Coffee Machine Error Code E-105: Boiler Connector MissingE-106Eversys Coffee Machine Error Code E-106: Steam Boiler OverheatingE-107Eversys Coffee Machine Error Code E-107: Pressure Sensor FailureS-000Eversys Coffee Machine Error Code S-000: Initializing, Please WaitS-001Eversys Coffee Machine Error Code S-001: Coffee Boiler HeatingS-002Eversys Coffee Machine Error Code S-002: Left Hopper MissingS-003Eversys Coffee Machine Error Code S-003: Right Bean Hopper MissingS-004Eversys Coffee Machine Error Code S-004: Empty the Grounds Drawer

All 126 Eversys super-automatic coffee codes

→Model series

Eversys lines and model numbers we service

Current and older lines. Find the number on the data plate and open its series for the usual repairs.

FAQEversys questions
What should I do first when my Eversys shows a communication error?

Switch the machine off, wait ten seconds and switch it on again. If the E message returns, call us and we test the connections between the display, the processors and each of the units.

Why does my Cameo say W-037?

The milk system was cleaned without detergent. Use the Everclean detergent, one pump of 25 ml, as the cleaning cycle asks. If the message stays after a proper cleaning, we check the milk system and its pump.

Do you repair the Eversys Enigma and Shotmaster?

Yes. We service the Enigma, Shotmaster e'2 and e'4, Cameo and E'Line. Have the model and the exact E, W or S message ready, and we plan the parts before we come out.

Book a visit

Book Eversys repair in Miami, Los Angeles, Houston, New York and San Diego

Tell us the maker, the model number from the data plate and what the unit is doing. We confirm a three-hour arrival window and give you a written price before any work starts.

☎ Call our office ▤ Schedule a Visit