Error code · Alto-Shaam · Combi ovens

Alto-Shaam Combi Oven Error Code E108: Cooling Fan Warning

E108 Cooling Fan Failure means the control (relay) board temperature is between 140 F (60 C) and 176 F (80 C). Check the cooling fan and its air intake, and call for service if the message returns.

Medium · inspection needed

Low: an early warning; the oven keeps running while the board is under 176 F (80 C).

Code
E108
Maker
Alto-Shaam
Equipment
Combi ovens
Applies to
Combitherm CT PROformance (CTP) and CT Classic (CTC)

What does Alto-Shaam error code E108 mean?

This is the early-warning step for board overheating. The relay board has a temperature sensor, and the control compares it against two levels. When the reading sits between 140 F (60 C) and 176 F (80 C), the control posts E108 Cooling Fan Failure. Once it passes 176 F (80 C), E02 Control Temperature High takes over. So E108 is the board getting warmer than it should, and E02 is the board being too hot. The manual lists two causes, a cooling fan that is not working and a cooling fan air intake that is blocked. Both reduce the air passing over the board. The practical value of E108 is that it comes before E02, giving time to clear a blocked intake or call for a fan before the oven shuts down. If the fan runs and the intake is clean, a technician looks at the board and its sensor.

Affected models and control systems

Six sizes of CTP and CTC combi oven, 6-10 to 20-20, electric and gas, which cool their relay board with a fan.

Code numbers and their meaning can change between control generations. We match the full model and control before acting on a code.

What you may notice

  • E108 Cooling Fan Failure on the display
  • Warm air at the control area vents
  • Code appearing after long hot service

Possible causes

Listed in Alto-Shaam's documentation

  • Cooling fan malfunction
  • Cooling fan air intake blocked

Other likely causes — what usually sits behind error code E108 on this control. A technician confirms which one it is before any part is replaced.

  • Lint or grease built up on the intake screen from a busy cooking line
  • Ambient kitchen heat so high that the incoming cooling air is already warm

Safe checks before calling for service

✓ What an operator can do
  1. Look at the oven's air intake and vents and clear any visible lint or boxes.
  2. Check that the oven has the clearance the installation guide asks for.
  3. Let the oven rest if it has run for a long time without a break.
  4. If E108 returns, tell the technician how long the oven had been running and whether E02 ever appeared.

How a technician diagnoses error code E108

  1. Read the code and history for E02.
  2. Check that the cooling fan runs and measure its supply.
  3. Inspect and clear the air intake path.
  4. Take a board temperature reading in operation.
  5. Replace the fan if weak, and test the sensor circuit if the board runs warm with good airflow.
! Leave this to a technician
  • The fan and board are behind the panel with live voltage.
  • Board temperature must be read while the oven is running.
  • Continued overheating can damage the control board.

How error code E108 differs from similar codes

E02 is the stronger warning at 176 F (80 C); E108 covers 140 F (60 C) to 176 F (80 C).

Technical reference

Maker documentation
Alto-Shaam owner support
Edition
MN-35949 Rev 08 03/22
Models / control
Combitherm CT PROformance (CTP) and CT Classic (CTC)
Section
Error Codes, pp. 25-31
Checked
October 2026

We use the maker's document to read the code and do not reproduce it. Always confirm the complete model and control before applying these steps.

E108Questions about Alto-Shaam error code E108
Is E108 urgent?

It is a warning step before E02, so clear the cause soon.

How is it different from E02?

E02 is above 176 F (80 C); E108 is between 140 F (60 C) and 176 F (80 C).

Will it clear by itself?

It may once the board cools, but the cause remains.

Book a visit

Need help with Alto-Shaam error code E108?

A technician confirms the cause on site and gives you the price in writing before any work starts.

☎ Call our office ▤ Schedule a Visit