Booking today · Miami, Los Angeles, Houston, New York and San Diego · three-hour arrival windows Independent commercial equipment repair · Every maker on this site Mon–Fri 7:00 AM - 8:00 PM · Sat 8:00 AM - 6:00 PM
(844) 393-0816 Schedule a Visit
Error code · Alto-Shaam · Combi ovens

Alto-Shaam Combi Oven Error Code E48: B10 Point 3 Shorted

E48 B10 - Point 3 Fault means sensing point 3 of the multipoint core probe B10 is shorted to ground. Press the Start icon to acknowledge it, check the cable, and arrange a probe test if it returns.

Medium · inspection needed

Low: core-probe cooking is affected, and time-based programs continue.

Code
E48
Maker
Alto-Shaam
Equipment
Combi ovens
Applies to
Combitherm CT PROformance (CTP) and CT Classic (CTC)

What does Alto-Shaam error code E48 mean?

Sensing point 3 of the multipoint core probe B10 has its own line to the control board. The control expects that line to carry a temperature signal and to be isolated from ground. If it sees a short to ground, it posts E48 B10 - Point 3 Fault. The manual's only listed cause is a probe that is miswired or has malfunctioned. Cables take the most abuse, since a probe cord is pulled, bent and often caught in a door, so a pinched cable is a common route to a short. The code differs from E28, where point 3 is open or defective. Pressing Start acknowledges the message and the oven then tries to return to normal operation, but a short does not heal, so the control reports the probe again whenever it is used. A technician measures the third line against ground to confirm whether the probe or the oven wiring carries the short.

Affected models and control systems

Alto-Shaam Combitherm CT PROformance and CT Classic combi ovens in sizes 6-10, 10-10, 7-20, 10-20, 20-10 and 20-20, electric and gas, fitted with the multipoint core probe.

Code numbers and their meaning can change between control generations. We match the full model and control before acting on a code.

What you may notice

  • E48 Point 3 message on the display
  • Probe-based cooking program failing
  • Third temperature point missing or incorrect

Possible causes

Listed in Alto-Shaam's documentation

  • Probe B10 miswired or failed

Other likely causes — what usually sits behind error code E48 on this control. A technician confirms which one it is before any part is replaced.

  • A cable pinched by the door gasket and flattened until its insulation split
  • A strain-relief failure at the handle end where the third wire touches the shield

Safe checks before calling for service

✓ What an operator can do
  1. Press the Start icon once to acknowledge E48.
  2. Inspect the cable along its whole length for flat spots or nicks.
  3. Plug the probe back in after drying the contacts.
  4. If E48 returns, do not use the probe and cook by time until it is tested.

How a technician diagnoses error code E48

  1. Read the code and see which other point codes were logged.
  2. Look over the probe cable, handle and plug.
  3. Meter line 3 to ground with the probe disconnected.
  4. Test the oven receptacle wiring for a short to the chassis.
  5. Replace the probe if the short follows it.
! Leave this to a technician
  • Finding a short means isolating wires with a meter.
  • The receptacle ties into the live control wiring.
  • The probe checks food safety and should be accurate.

How error code E48 differs from similar codes

E28 is point 3 open or defective, while E48 is point 3 shorted to ground; E46, E47 and E49 are points 1, 2 and 4.

Technical reference

Maker documentation
Alto-Shaam owner support
Edition
MN-35949 Rev 08 03/22
Models / control
Combitherm CT PROformance (CTP) and CT Classic (CTC)
Section
Error Codes, pp. 25-31
Checked
October 2026

We use the maker's document to read the code and do not reproduce it. Always confirm the complete model and control before applying these steps.

E48Questions about Alto-Shaam error code E48
What caused my cable to short?

The manual lists only a failed or miswired probe, though a crushed cable is a plausible cause.

Can I use the other points?

Not reliably, the control flags the probe as a whole.

Is E48 permanent?

A short usually stays until the damaged part is replaced.

Book a visit

Need help with Alto-Shaam error code E48?

A technician confirms the cause on site and gives you the price in writing before any work starts.

☎ Call our office ▤ Schedule a Visit