Eversys Coffee Machine Error Code S-103: Depressurizing Steam Boiler

S-103 shows "Depressurize steam boiler..." while the machine releases pressure from the steam boiler. Wait for it to finish, or abort with the stop button in the upper left corner.

Medium · inspection needed

Low: a progress message for a normal routine.

Code
S-103
Maker
Eversys
Equipment
Super-automatic coffee
Applies to
Eversys Cameo range (Cameo/Core, Classic, ST, in-box), e'Support article

What does Eversys error code S-103 mean?

S-103 is a progress message on the Eversys Cameo. The screen reads "Depressurize steam boiler..." and the e'Support table says it is displayed during the process of depressurizing the steam boiler. The action is to wait until the boiler is depressurized, or to abort by pressing the stop button in the upper left corner. Like S-102, it describes a routine the machine is running on purpose, and no cause is listed because nothing has gone wrong. The table does not say why the pressure is being released, how long it takes or what follows. We can only say that S-101, which asks for the machine to be switched off, belongs to the same group and appears after the boiler has been emptied or depressurized. If the stop button is used, the table does not describe the state the boiler is left in, so avoid treating an aborted run as a finished one. Depressurizing is a safety-related step: the control brings the boiler down before anyone works on it or before the machine is powered off.

Affected models and control systems

Eversys Cameo range (Cameo/Core, Classic, ST and in-box versions). The message is listed in Eversys' e'Support table of operator stop messages for Cameo, and the table gives no board revision or model limit.

Code numbers and their meaning can change between control generations. We match the full model and control before acting on a code.

What you may notice

  • The screen shows "Depressurize steam boiler..."
  • Steam drinks are unavailable
  • A hiss or release of steam may be heard

Possible causes

Likely causes — what usually sits behind error code S-103 on this control. A technician confirms which one it is before any part is replaced.

  • Steam boiler depressurizing routine is running
  • The routine was started for a shut-down and the operator did not notice
  • The boiler was still under pressure after a long steam session, so the release takes longer
  • A stop was pressed in the middle, then the routine restarted, so the message returned

Safe checks before calling for service

✓ What an operator can do
  1. Let the machine complete the routine and keep away from the steam outlet.
  2. Do not open any panel or touch the boiler area.
  3. If you did not mean to start it, press the stop button in the upper left corner.
  4. Note what you did before the message, and whether S-101 followed.

How a technician diagnoses error code S-103

  1. Confirm S-103 against the Cameo table and ask what led to it.
  2. Watch for the end of the routine and the next message.
  3. Check for pressure that does not fall, which suggests a blocked release path.
  4. Inspect pressure and level parts for correct readings.
  5. Test relief and drain parts if the routine does not complete.
! Leave this to a technician
  • Pressurized steam parts can scald if opened too early.
  • The pressure and level parts connect to mains-powered controls inside the machine.
  • Judging a stuck release needs a gauge and training.

How error code S-103 differs from similar codes

S-103 is the pressure-release stage next to S-102, which empties the boiler.

Technical reference

Document
Operator stop messages for Cameo (S-XXX)
Models / control
Eversys Cameo range (Cameo/Core, Classic, ST, in-box), e'Support article
Section
Web page table of S-numbers, Infos messages and Explanations / Remedies (no page numbers)
Checked
October 2026

We use the maker's document to read the code and do not reproduce it. Always confirm the complete model and control before applying these steps.

S-103Questions about Eversys error code S-103
Is it safe to touch the machine during S-103?

Keep away from the steam outlet and boiler area until it finishes. The table only says to wait.

Can I abort it?

Yes, with the stop button in the upper left corner.

Will S-101 follow?

The table says S-101 appears after the boiler has been emptied or depressurized, so it can.