Booking today · Miami, Los Angeles, Houston, New York and San Diego · three-hour arrival windows Independent commercial equipment repair · Every maker on this site Mon–Fri 7:00 AM - 8:00 PM · Sat 8:00 AM - 6:00 PM
(844) 393-0816 Schedule a Visit
Error code · Eversys · Super-automatic coffee

Eversys Coffee Machine Error Code S-106: Initializing, Please Wait

S-106 shows "Initialize, please wait..." while the machine starts up. Just wait until initialization is finished. If it never ends, switch the machine off and on once and call us if it repeats.

Medium · inspection needed

Low: a start-up message that ends by itself.

Code
S-106
Maker
Eversys
Equipment
Super-automatic coffee
Applies to
Eversys Cameo range (Cameo/Core, Classic, ST, in-box), e'Support article

What does Eversys error code S-106 mean?

S-106 is a start-up message on the Eversys Cameo. The screen reads "Initialize, please wait..." and the e'Support table gives the meaning in one line: the machine is initializing. The action is equally short: just wait until the coffee machine is initialized. When the machine is switched on, the control has to bring its parts to a known starting state before it accepts orders, and while that happens it shows this text. No causes are listed because it is an ordinary stage of every start, and there is nothing to fix. The table gives no length of time and does not say what follows, but other messages in the same table, such as S-105 (rinse necessary), can appear after start-up. The practical point for staff is patience: pressing buttons or switching the machine off during initialization only starts the process over. A technician only needs to look at it if the message does not end after what feels like a clearly long time.

Affected models and control systems

Eversys Cameo range (Cameo/Core, Classic, ST and in-box versions). The message is listed in Eversys' e'Support table of operator stop messages for Cameo, and the table gives no board revision or model limit.

Code numbers and their meaning can change between control generations. We match the full model and control before acting on a code.

What you may notice

  • The screen shows "Initialize, please wait..."
  • The machine has just been switched on
  • Motors or valves may move on their own during start-up

Possible causes

Likely causes — what usually sits behind error code S-106 on this control. A technician confirms which one it is before any part is replaced.

  • Machine is starting up and bringing its parts to their starting position
  • Power was interrupted just before, so the machine restarts from the beginning
  • A part that cannot reach its start position keeps the initialization from finishing
  • Staff keep pressing keys and restarting, so the process never completes

Safe checks before calling for service

✓ What an operator can do
  1. Wait and keep hands away from the brewing area and outlet.
  2. Do not press keys or switch the machine off during initialization.
  3. If it stays on this message much longer than usual, switch off at the main switch and on again once.
  4. Note how long it took and what message came next.

How a technician diagnoses error code S-106

  1. Confirm S-106 against the Cameo table and ask how long the start-up lasts.
  2. Observe which parts move and whether any stops partway.
  3. Check the next message to see where the start-up stalls.
  4. Check supply voltage and the connection between display and control.
  5. Test the stalled part before replacing it.
! Leave this to a technician
  • Moving parts start by themselves during initialization, so hands near them can be pinched.
  • A stalled start-up usually means a movement or sensor check that needs a meter and service access.
  • Supply and wiring checks involve live circuits.

How error code S-106 differs from similar codes

S-106 is the first stage of start-up. S-105 can follow, asking for the rinse before the boiler heats.

Technical reference

Document
Operator stop messages for Cameo (S-XXX)
Models / control
Eversys Cameo range (Cameo/Core, Classic, ST, in-box), e'Support article
Section
Web page table of S-numbers, Infos messages and Explanations / Remedies (no page numbers)
Checked
October 2026

We use the maker's document to read the code and do not reproduce it. Always confirm the complete model and control before applying these steps.

S-106Questions about Eversys error code S-106
Can I use the machine during initialization?

No. Wait until it finishes.

Will it end by itself?

Yes. The table says to just wait.

What if it keeps repeating?

Call us. Tell us how long it ran and what message came last.

Book a visit

Need help with Eversys error code S-106?

A technician confirms the cause on site and gives you the price in writing before any work starts.

☎ Call our office ▤ Schedule a Visit