Eversys Coffee Machine Error Code S-107: Security Probe Problem

S-107 says there is a steam boiler security probe problem. The probe circuit is open, so steam and hot water are disabled and heating is switched off. Keep the main switch off for ten seconds and on once; if S-107 returns, the machine stays off until you call us.

Medium · inspection needed

High: heating is switched off for safety, so steam and hot water stay out of service until the circuit is repaired.

Code
S-107
Maker
Eversys
Equipment
Super-automatic coffee
Applies to
Cameo (S-xxx stop messages)

What does Eversys error code S-107 mean?

The steam boiler has a security probe, a safety input the control watches before it will heat. The probe circuit has to be complete for the control to allow heating. If the circuit is open, the control cannot confirm that the boiler is safe, so it disables steam and hot water, switches heating off and displays S-107. Staff lose steam and hot water, and the machine will not heat until the circuit is restored. The probe protects the boiler, which is why the control will not work around it. An open circuit can come from the probe itself, from its wiring, from the plug, or from the board input that reads the circuit. In hard water, scale can also build up on the probe and change what it reads. The display cannot separate these, so a technician tests the circuit section by section. The boiler area is hot and carries mains power, which is why the owner's guide gives operators only one restart and no panel work. A returning S-107 means the machine stays off until it has been tested. The display shows S-107.

Affected models and control systems

This applies to the Eversys Cameo with S-xxx stop messages. It concerns the steam boiler security probe circuit, a different input from the pressure sensor in E-107.

Code numbers and their meaning can change between control generations. We match the full model and control before acting on a code.

What you may notice

  • Steam and hot water are disabled
  • Boiler does not heat
  • S-107 stays after a restart
  • Stop message right after power-up

Possible causes

Listed in Eversys's documentation

  • Open security probe or damaged probe wiring
  • Loose security probe connector
  • Open probe circuit at the board
  • Scale on the probe in hard water

Other likely causes — what usually sits behind error code S-107 on this control. A technician confirms which one it is before any part is replaced.

  • A probe tip that has scaled over and no longer conducts through the water
  • A harness near the boiler that has hardened from heat and opened inside the insulation

Safe checks before calling for service

✓ What an operator can do
  1. Do not use steam or hot water while the message is showing.
  2. Keep the main switch off for ten seconds and then on, one time only.
  3. A returning S-107 means the machine stays off until you call us.
  4. Do not open any panel, because the boiler area is hot and carries mains power. Note whether S-107 appeared before or after the machine heated.

How a technician diagnoses error code S-107

  1. Cool the machine and isolate power.
  2. Inspect the probe, its plug and the visible wiring.
  3. Measure continuity of the probe circuit with a meter.
  4. Check the board input for the probe signal.
  5. Descale or clean the probe if scale is present.
  6. Replace the probe, harness or board section that fails the test.
! Leave this to a technician
  • The security probe is the boiler's safety input, and it must not be bypassed or tested casually.
  • The probe circuit sits in a hot area with mains-powered heater wiring.
  • Descaling or replacing the probe means draining and opening the steam boiler.

Technical reference

Document
Eversys eSupport: Operator stop messages for Cameo (S-XXX)
Models / control
Cameo (S-xxx stop messages)
Section
Web page table of S-numbers, Infos messages and Explanations / Remedies (no page numbers)
Checked
October 2026

We use the maker's document to read the code and do not reproduce it. Always confirm the complete model and control before applying these steps.

S-107Questions about Eversys error code S-107
Why won't it heat at all with S-107?

The safety probe circuit is open, and the control will not heat a boiler it cannot confirm is safe.

Can I restart it a few times?

Once only. If S-107 returns, keep the machine off and call us.