Eversys Coffee Machine Error Code W-044: CPU Machine Data Not Restored

W-044 means the machine data stored for the CPU could not be restored after a restart or update. The maker's table gives no operator action, so note what the machine is doing and call a technician.

Medium · inspection needed

Medium: stored settings may be missing, and the machine may not behave as it was set up.

Code
W-044
Maker
Eversys
Equipment
Super-automatic coffee
Applies to
Eversys Cameo range (Cameo/Core, Classic, ST, in-box), e'Support article

What does Eversys error code W-044 mean?

The Cameo keeps its machine data, meaning the settings that describe how this particular machine is set up, in stored memory. When the control restarts or its software is updated, it reads that data back. If the read-back does not work, it shows "CPU Machine Data not restored" as W-044. The maker's table explains only that the stored CPU machine data could not be restored, and it gives no action and no list of causes. We cannot say from the table whether drinks still run on factory values or whether settings were lost, so check the settings you rely on, such as recipes and cleaning times, before trusting them. Restoring machine data is not an operator task and needs the maker's service tools.

Affected models and control systems

Eversys Cameo range (Cameo/Core, Classic, ST and in-box versions), as covered by the maker's e'Support table of W-number warning messages.

Code numbers and their meaning can change between control generations. We match the full model and control before acting on a code.

What you may notice

  • W-044 appears after a restart or software update
  • Settings or recipes look different from before
  • The machine may run but behave oddly

Possible causes

Likely causes — what usually sits behind error code W-044 on this control. A technician confirms which one it is before any part is replaced.

  • Stored CPU machine data could not be restored after a restart or update
  • A software update that was interrupted partway through
  • A power loss while the CPU was saving machine data
  • A memory chip on the control board that no longer holds stored values

Safe checks before calling for service

✓ What an operator can do
  1. Write down the time of the last restart or update.
  2. Look at your usual recipes and cleaning settings to see whether they changed.
  3. Do not start a new update or reset on your own.
  4. Report W-044 with what you noticed in the settings.

How a technician diagnoses error code W-044

  1. Read the machine data and event history to see when the restore failed.
  2. Check the software version against the last one that ran cleanly.
  3. Reload the stored machine data from backup using the maker's tool, if one exists.
  4. Replace the CPU board only after the reload fails and the memory test points to it.
! Leave this to a technician
  • Reloading machine data needs the maker's service software and the data set for this exact machine.
  • Wrong data can change heating and safety settings, so it must be handled by trained service staff.

How error code W-044 differs from similar codes

Unlike W-043, which is only the display's memory, this one concerns the machine's own stored data.

Technical reference

Document
Operator warning messages for Cameo (W-XXX)
Models / control
Eversys Cameo range (Cameo/Core, Classic, ST, in-box), e'Support article
Section
Web page table of W-numbers, Infos messages and Explanations / Remedies (no page numbers)
Checked
October 2026

We use the maker's document to read the code and do not reproduce it. Always confirm the complete model and control before applying these steps.

W-044Questions about Eversys error code W-044
Is it safe to keep using the machine?

The table does not say. Check that drinks and temperatures look normal, and call service before relying on it.

Will it clear itself?

The table lists no action and no self-clearing. Expect it to need service.

Did I lose my recipes?

Possibly. The message says stored data was not restored, so check them.

Book a visit