Eversys Coffee Machine Error Code W-153: Telemetry Message
W-153 is a telemetry-related message that the maker says clears according to the telemetry settings. The table shows no display text for it and no operator action.
Low: a telemetry notice; nothing indicates it stops the machine.
- Code
- W-153
- Maker
- Eversys
- Equipment
- Super-automatic coffee
- Applies to
- Eversys Cameo range (Cameo/Core, Classic, ST, in-box), e'Support article
What does Eversys error code W-153 mean?
The Cameo can report its status to a remote telemetry service, and some messages relate to that link. W-153 is one of them. The maker's table gives no display text for it, which is why we cannot quote what the screen says. Its explanation is that the message will be cleared depending on the settings in the telemetry. In other words, it is not cleared by pressing a key or by a cleaning, and whether it stays or goes depends on how the telemetry has been set up for the machine. The table gives no cause and no instruction for the operator. It does not suggest that drinks are affected. Anyone who needs it gone for good should ask whoever manages the telemetry for the machine.
Affected models and control systems
Eversys Cameo range (Cameo/Core, Classic, ST and in-box versions), as covered by the maker's e'Support table of W-number warning messages.
Code numbers and their meaning can change between control generations. We match the full model and control before acting on a code.
What you may notice
- A W-153 entry on the display with no separate wording
- Drinks are not described as affected
- The message clears later without any action
Possible causes
Likely causes — what usually sits behind error code W-153 on this control. A technician confirms which one it is before any part is replaced.
- Telemetry activity that is cleared according to the telemetry settings
- Telemetry settings that keep the message active for a set period
- A weak network connection between the machine and the telemetry service
Safe checks before calling for service
- Check that drinks and cleaning cycles work normally.
- Leave the message alone and see whether it clears with the telemetry schedule.
- Do not unplug the network connection to force it.
- Tell the person who manages the telemetry if the message stays for days.
How a technician diagnoses error code W-153
- Open the telemetry settings and read the rules for this message.
- Check the network link and the reporting status.
- Confirm the telemetry portal sees the machine.
- Adjust the clear condition if the customer asks.
- Telemetry settings sit in protected service menus.
- Network and portal checks need the customer's account and the maker's tools.
How error code W-153 differs from similar codes
This one concerns telemetry only; it is not a drink or milk problem like the other W messages.
Technical reference
- Document
- Operator warning messages for Cameo (W-XXX)
- Models / control
- Eversys Cameo range (Cameo/Core, Classic, ST, in-box), e'Support article
- Section
- Web page table of W-numbers, Infos messages and Explanations / Remedies (no page numbers)
- Checked
- October 2026
We use the maker's document to read the code and do not reproduce it. Always confirm the complete model and control before applying these steps.
Related Eversys super-automatic coffee error codes
Do I have to do anything?
The table gives no operator action. It says the message is cleared depending on the telemetry settings.
Does it stop me making drinks?
Nothing in the table says it does.
Why is there no text on the screen?
The table lists no display text for W-153.
Need help with Eversys error code W-153?
A technician confirms the cause on site and gives you the price in writing before any work starts.