Error code · UniMac · Industrial laundry

UniMac Washer-Extractor Error Code Eio 44: Cold Valve Output Short

Eio 44 means the input and output board found the cold fill valve shorted, so it turned that output off and the control stopped the cycle. Shut the cold water supply valve if you can, power down, and call us.

Medium · inspection needed

High: the shorted cold valve output stops the cycle and can stress the board if restarted.

Code
Eio 44
Maker
UniMac
Equipment
Industrial laundry
Applies to
CHM1792C family washer-extractor (QN models, 20-100 lb) front-end control

What does UniMac error code Eio 44 mean?

Eio 44 is the cold-side partner of Eio 43 on a UniMac QN washer-extractor. The input and output board watches the current it sends to the cold fill valve coil. Excess current through the coil or its wiring makes the board turn that output off, and the control stops the cycle. The checks are very similar to the hot side, though the problem may sit in a different coil or wire. Because the cold valve is used in nearly every wash and rinse, a washer that stops with Eio 44 often does so in the first fill. The manual lists the cold fill valve coil resistance, the valve wiring and connector, moisture near the valve, and the I/O board output stage. Cold water pipes sweat in humid rooms, and that condensation can run onto a connector and short it. Record the code, shut the cold supply, power down, wipe up water and keep the area dry for our visit.

Affected models and control systems

This applies to the CHM1792C family of UniMac QN washer-extractors, 20 to 100 lb, front-end control, for example the UCA020QN. Eio 44 is the cold side of the fill valve short codes.

Code numbers and their meaning can change between control generations. We match the full model and control before acting on a code.

What you may notice

  • Eio 44 on the display and the cycle stopped
  • No cold water entering the tub
  • Hot fills that still work
  • Sweating pipes or damp around the connector

Possible causes

Listed in UniMac's documentation

  • Cold fill valve coil resistance
  • Valve wiring and connector
  • Moisture near the valve
  • I/O board output stage

Other likely causes — what usually sits behind error code Eio 44 on this control. A technician confirms which one it is before any part is replaced.

  • A cold valve connector corroded by condensation on a sweating supply line
  • A coil winding shorted after years of cycling on a busy wash line
  • A valve harness pinched against the frame when the cabinet was last serviced

Safe checks before calling for service

✓ What an operator can do
  1. Record Eio 44 and shut the cold water supply valve at the wall if you can reach it.
  2. Power the machine down.
  3. Wipe up any water on the floor.
  4. Call us to check the valve, and keep the area dry.

How a technician diagnoses error code Eio 44

  1. Read the code and check whether the hot valve fills normally.
  2. With power locked out and water shut, inspect the cold valve connector and wiring.
  3. Measure the cold valve coil resistance.
  4. Check for condensation or dripping along the supply line.
  5. Replace the valve or connector, then test the board output.
! Leave this to a technician
  • A shorted valve coil carries live voltage in a wet area.
  • The board output cannot be judged until the valve is cleared as the cause.
  • Shutoff valves and fittings are under water pressure when a valve is changed.

Technical reference

Document
Washer-Extractor Programming CHM1792C_SVG, Part No. F8641001ENR4, Error Codes Table 29 (pp. 100-107)
Maker documentation
UniMac owner support
Edition
Part No. F8641001ENR4, January 2020
Models / control
CHM1792C family washer-extractor (QN models, 20-100 lb) front-end control
Section
Error Codes, Table 29, pp. 100-108 (PDF pages equal printed pages)
Checked
October 2026

We use the maker's document to read the code and do not reproduce it. Always confirm the complete model and control before applying these steps.

Eio 44Questions about UniMac error code Eio 44
Why would cold water cause a short?

Sweating pipes can drip onto the valve connector. Moisture is one of the listed causes.

Will hot water still run?

Probably, since Eio 44 involves only the cold valve output.

Is it the same as Eio 43?

The checks match, but Eio 43 is the hot valve and Eio 44 is the cold valve.

Book a visit

Need help with UniMac error code Eio 44?

A technician confirms the cause on site and gives you the price in writing before any work starts.