Kold-Draft 60 Series Ice Cube Makers
Current line. 43 model numbers in this series.
Model numbers in this series
Find yours on the data plate. Letters after the base number usually mark the voltage, finish or door and do not change the repair.
- GT361AHK
- GT361AC
- GT361LC
- GT361LHK
- GT364AHK
- GT364AC
- GT364LC
- GT364LHK
- GT561AHK
- GT561AC
- GT561LC
- GT561LHK
- GT564AHK
- GT564AC
- GT564LC
- GT564LHK
- GT564R
- GB561AHK
- GB561AC
- GB561LC
- GB561LHK
- GB564AHK
- GB564AC
- GB564AK
- GB564LC
- GB564LHK
- GB564R
- GB1064AHK
- GB1064AC
- GB1064LHK
- GB1064LC
- GB1064RHK
- GB1064RC
- GB1064X
- RC214APV
- RC314APV
- T271
- T274
- T281
- T284
- SC200
- SC201
- SC204
Repairs this series usually needs
- Code 20 water plate closing problems
- Code 30 long freeze and code 40 short freeze
- Code 60 fill cycle too long
- Evaporator probe out of adjustment
- Dirty air-cooled condenser in hot rooms
The 60 Series covers the GT361, GT364, GT561, GT564, GB561, GB564 and GB1064 machines, plus the remote versions with RC214 and RC314 condensers. They make the large, clear, slow-melting cubes bartenders like, and an electronic controller flashes LED codes from 10 to 90.
The controller revision changes what the codes mean. Revision 1.6 and later removed codes 10 and 50, for example, and changed how 20, 30, 40 and 60 behave. The revision number is printed on a sticker on the processor chip.
We check the water plate, fill, probe adjustment and condenser first, then the refrigeration side. Heat matters, because the maker lists a top air temperature of 90 F. Please have the controller revision and the model number ready when you call.
About this series
- Clear ice cube makers in GT and GB models with R-404a
- Self-contained air-cooled (A) or liquid-cooled (L), or remote (R) with pre-charged RC214APV or RC314APV condensers
- K4B-style controller with codes 10 to 90 on LEDs
- Ambient air between 45 and 90 F
- Evaporator temperature dial that sets harvest termination between 35 and 60 F
Kold-Draft ice machines codes
Other Kold-Draft ice machines series
What does the clear ice mean for service?
These machines freeze water in a controlled way to make clear cubes. That makes water quality, the water plate and the evaporator probe adjustment important.
Where is the controller revision?
There is a sticker on the processor chip, for example K4B-1.2 for revision 1.2. Tell us the number and we know how to read the codes.
Does summer heat affect it?
Yes. The maker lists an air limit of 90 F, and higher temperatures lower capacity and raise head pressure. A clean condenser and clear air help.
Book repair for your Kold-Draft 60 Series Ice Cube Makers
Tell us the maker, the model number from the data plate and what the unit is doing. We confirm a three-hour arrival window and give you a written price before any work starts.