Booking today · Miami, Los Angeles, Houston, New York and San Diego · three-hour arrival windows Independent commercial equipment repair · Every maker on this site Mon–Fri 7:00 AM - 8:00 PM · Sat 8:00 AM - 6:00 PM
(844) 393-0816 Schedule a Visit
Error code · Speed Queen · Washers

Speed Queen CHM495R Washer Error Code Ed03: Tachometer Error

Ed03 on a Design 2 or 3 CHM495R washer-extractor is a tachometer error: the tach input was damaged at power-up, or no signal came back after the motor output started. Turn the power off and call us if it returns.

Medium · inspection needed

High: with no tach signal the machine cannot confirm the drum is turning, so it stops.

Code
Ed03
Maker
Speed Queen
Equipment
Washers
Applies to
CHM495R family washer-extractor front-end control (20-100 lb)

What does Speed Queen error code Ed03 mean?

The tachometer is the sensor that tells the drive how fast the motor is turning. The control uses it to know the drum is moving, so it can ramp the speed and confirm the spin. On a CHM495R of Design 2 or 3, Ed03 means the tach input was damaged at power-up or that no signal came back after the motor output started. With no proof the drum is turning, the control stops the cycle. The owner's manual says to power down and look at the H3 connection on the drive and at the tach connections. That points at the signal path: a loose H3 tach connection on the drive, a tach wire damaged at the motor, a motor tach that sends no signal, or a drive board tach input that was damaged at power-up. Since the motor may be fine, replacing it first would be an expensive guess. The measurement is simple, but it happens inside the cabinet.

Affected models and control systems

This page covers Design 2 and Design 3 machines of the CHM495R family washer-extractor front-end control. Other drive messages on the same machine have their own codes.

Code numbers and their meaning can change between control generations. We match the full model and control before acting on a code.

What you may notice

  • The drum does not start to turn
  • Ed03 shows soon after a cycle begins
  • The door stays locked briefly after power-off

Possible causes

Listed in Speed Queen's documentation

  • A loose H3 tach connection on the drive
  • A tach wire damaged at the motor
  • A motor tach that sends no signal
  • A drive board tach input that was damaged at power-up

Other likely causes — what usually sits behind error code Ed03 on this control. A technician confirms which one it is before any part is replaced.

  • A tach wire rubbed through where it leaves the motor housing
  • A drive input stressed by a power surge at the moment the machine started

Safe checks before calling for service

✓ What an operator can do
  1. Begin by turning the power off, following the owner's manual.
  2. Once the lock has released, the door can be opened; not before.
  3. The connections inside the cabinet are not for owners to check.
  4. If the code returns, note when it appeared in the cycle, and request a visit.

How a technician diagnoses error code Ed03

  1. Read the code and confirm the machine is a Design 2 or 3.
  2. Inspect the H3 tach connection on the drive for seating and damage.
  3. Trace the tach wire to the motor for rub marks and breaks.
  4. Check the tach signal while the motor is commanded to start.
  5. Replace the tach, wire or drive only after the signal path is tested.
! Leave this to a technician
  • The H3 connection sits on a drive that carries high voltage, so it is not safe to handle without training.
  • The tach signal can only be proved with the motor commanded to run.
  • A bad tach input and a bad tach look the same without a signal test.

Technical reference

Document
Washer-Extractor Programming CHM495R_SVG, Part No. F8208501ENR10, March 2017, Error Codes (pp. 36-37)
Edition
Part No. F8208501ENR10, March 2017
Models / control
CHM495R family washer-extractor front-end control (20-100 lb)
Section
Error Codes table, pp. 36-37 (E Pr only on Design 1 models; Ed01-Ed11 on Design 2 and 3 models)
Checked
October 2026

We use the maker's document to read the code and do not reproduce it. Always confirm the complete model and control before applying these steps.

Ed03Questions about Speed Queen error code Ed03
Is the motor bad if I see Ed03?

Not necessarily. The tach signal path can fail while the motor is fine.

Why does it show at start-up?

The control checks for a tach signal as soon as the motor output starts.

Does Ed03 apply to every CHM495R?

No. It applies to Design 2 and 3 machines.

Book a visit

Need help with Speed Queen error code Ed03?

A technician confirms the cause on site and gives you the price in writing before any work starts.

☎ Call our office ▤ Schedule a Visit