Booking today · Miami, Los Angeles, Houston, New York and San Diego · three-hour arrival windows Independent commercial equipment repair · Every maker on this site Mon–Fri 7:00 AM - 8:00 PM · Sat 8:00 AM - 6:00 PM
(844) 393-0816 Schedule a Visit
Model series · McCall · Reach-in refrigerators

McCall Series I Reach-In Refrigerators

Older line. 6 model numbers in this series.

01Model numbers

Model numbers in this series

Find yours on the data plate. Letters after the base number usually mark the voltage, finish or door and do not change the repair.

  • MCCR1
  • MCCR1-S
  • MCCR2
  • MCCR2-S
  • MCCR3
  • MCCR3-S

Repairs this series usually needs

  1. E1 or other E-code read-out
  2. Cabinet warm or iced evaporator
  3. Dirty condenser
  4. Door gasket wear
  5. Delay after power is applied

The Series I is an older McCall reach-in refrigerator with an aluminum interior, in one, two and three sections. The plate numbers are MCCR1, MCCR1-S, MCCR2 and similar. The electronic control self-checks and shows an error read-out such as E1 when it finds a problem.

The refrigerators are set near 38 F at the factory, and the control waits up to ten minutes after power is applied before it starts operations, so a cabinet that seems idle after an outage may be fine. We read the code, then check the condenser, the gasket and the probe.

These are older cabinets still in service, and we repair them. We tell you plainly if the cabinet is past a sensible repair, and we give a written price before any part is ordered.

About this series

  • One-, two- and three-section reach-in refrigerators with an aluminum interior
  • Electronic temperature control with a digital display
  • Models such as MCCR1, MCCR1-S and MCCR2
  • Six model numbers
FAQMcCall Series I Reach-In Refrigerators questions
Why is my cabinet idle after the power came back?

The control waits up to ten minutes after power is applied before it starts operations. Give it time before you assume something is wrong. Unplugging it again restarts the wait.

What does E1 mean on this control?

The control found a problem and shows an error read-out. The display does not define each code, so we test the cabinet to find the cause.

How cold is it set at the factory?

Near 38 F for refrigerators and near 3 F for freezers. Allow about eight hours between adjustments so the cabinet can settle before you judge it.

Book a visit

Book repair for your McCall Series I Reach-In Refrigerators

Tell us the maker, the model number from the data plate and what the unit is doing. We confirm a three-hour arrival window and give you a written price before any work starts.

☎ Call our office ▤ Schedule a Visit