Booking today · Miami, Los Angeles, Houston, New York and San Diego · three-hour arrival windows Independent commercial equipment repair · Every maker on this site Mon–Fri 7:00 AM - 8:00 PM · Sat 8:00 AM - 6:00 PM
(844) 393-0816 Schedule a Visit
Model series · Ultrafryer · Fryers

Ultrafryer UltraGold P30-14 and P30-18 Gas Fryers

Current line. 16 model numbers in this series.

01Model numbers

Model numbers in this series

Find yours on the data plate. Letters after the base number usually mark the voltage, finish or door and do not change the repair.

  • B-P30-14-2-UCP
  • B-P30-14-3-UCP
  • B-P30-14-4-UCP
  • B-P30-14-5-UCP
  • B-P30-14-6-UCP
  • B-P30-18-2-UCP
  • B-P30-18-3-UCP
  • B-P30-18-4-UCP
  • B-P30-18-5-UCP
  • B-P30-18-6-UCP
  • B-P30-18-3-UC
  • B-P30-18-4-UC
  • B-P30-18-5-UC
  • B-P30-18-6-UC
  • F-P30-18
  • F-P30-18-H

Repairs this series usually needs

  1. PROBE message on the UltraStat 23
  2. Over-temperature alarm
  3. FILTER prompt keeps returning
  4. Burner will not light
  5. Slow recovery

The P30 is the main UltraGold gas fryer, built in 14 and 18 inch widths with a phased-array heat exchanger called PAR-3. Model numbers read like B-P30-14-3-UCP, where the digits near the end give the number of vats and UCP means UltraClear Plus filtration. The UltraStat 23 runs the control.

On these batteries we check the probe and the controller first, since that is where a PROBE message and an over-temperature alarm start. Ignition, the gas valve and the high limit come next, and we confirm the filtration side too.

If the oil level has dropped below the fill line, the limit can trip, so keep the oil topped up. If you smell gas near a P30, step outside and phone the gas utility from there.

About this series

  • Gas tube fryers with a phased-array heat exchanger
  • UltraClear Plus filtration
  • UltraStat 23 control
  • 35 to 45 lb per 14 inch vat
FAQUltrafryer UltraGold P30-14 and P30-18 Gas Fryers questions
What does UCP in the model number mean?

UCP stands for UltraClear Plus, the built-in filtration. A model that ends in UC has the standard filter instead, so the last letters tell us which filter system to check.

My P30 shows PROBE. What now?

Switch it off, let it cool and make sure the probe is plugged in. If the message returns, call us to test the probe, its wiring and the controller before the fryer cooks again.

Do you service full batteries?

Yes, every vat. We check the burners, the probes, the controls and the filter system together, so the whole battery is working before we leave, and we quote the work in writing first.

Book a visit

Book repair for your Ultrafryer UltraGold P30-14 and P30-18 Gas Fryers

Tell us the maker, the model number from the data plate and what the unit is doing. We confirm a three-hour arrival window and give you a written price before any work starts.

☎ Call our office ▤ Schedule a Visit