Booking today · Miami, Los Angeles, Houston, New York and San Diego · three-hour arrival windows Independent commercial equipment repair · Every maker on this site Mon–Fri 7:00 AM - 8:00 PM · Sat 8:00 AM - 6:00 PM
(844) 393-0816 Schedule a Visit
Model series · Ultrafryer · Fryers

Ultrafryer UltraPro14 Infrared Premix Gas Fryers

Current line. 3 model numbers in this series.

01Model numbers

Model numbers in this series

Find yours on the data plate. Letters after the base number usually mark the voltage, finish or door and do not change the repair.

  • B-IRS-14
  • F-IRS-14
  • B-IRC-14-B

Repairs this series usually needs

  1. Ignition lockout
  2. No spark or no blower
  3. Puffing at start-up
  4. Oil temperature runs off target
  5. High limit shuts the system down

UltraPro14 is the 14 inch infrared premix gas fryer. Models are B-IRS-14, F-IRS-14 and B-IRC-14-B. A blower mixes gas and air for the infrared burner, and an electrode lights it.

The usual problems are an ignition lockout, no spark or no blower. A cracked electrode or wrong gas pressure can cause puffing at start-up. If the heat runs too high, we check the probe, the temperature setting and the high limit. The limit can also shut things down when oil falls below the minimum fill line.

High kitchen temperatures and loose wiring can cause problems that come and go, so we check connections too. Tell us what the fryer did before it stopped when you book. Name the model when you call, B-IRS-14, F-IRS-14 or B-IRC-14-B.

About this series

  • Infrared premix gas fryers
  • 14 inch width
  • Models B-IRS-14, F-IRS-14 and B-IRC-14-B
  • Electrode ignition with a blower
FAQUltrafryer UltraPro14 Infrared Premix Gas Fryers questions
Why does my UltraPro14 lock out?

The gas valve, the electrode or the ignition module may be the cause. The gas supply comes first, then each of those parts in turn, and you hear the cost before we repair anything.

What causes puffing when it starts?

Wrong gas pressure or a cracked electrode can cause puffing at start-up. Should you ever notice gas in the air, go outside and call the utility before anything else.

Why does the high limit shut it down?

Low oil, a bad probe or a control problem can trip it. Let the oil cool, make sure it sits above the minimum fill line, and call us if the limit trips again.

Book a visit

Book repair for your Ultrafryer UltraPro14 Infrared Premix Gas Fryers

Tell us the maker, the model number from the data plate and what the unit is doing. We confirm a three-hour arrival window and give you a written price before any work starts.

☎ Call our office ▤ Schedule a Visit