Nor-Lake LogiTemp Walk-In Error Code A1A: AUX1 Sensor Shorted or Open
A1A is the LogiTemp alarm for the AUX1 temperature sensor reading shorted or open on a Nor-Lake walk-in cooler or freezer. Whatever the AUX1 input was watching goes unmonitored until the reading comes back. Note the code and LED color, confirm the box temperature with a thermometer and call us if A1A stays.
Medium: an auxiliary reading is lost, but the main box temperature control is still working.
- Code
- A1A
- Maker
- Nor-Lake
- Equipment
- Walk-in coolers & freezers
- Applies to
- LogiTemp / KE2 Evap OEM (Split-Pak systems, A1 refrigerants)
What does Nor-Lake error code A1A mean?
The KE2 Evap OEM controller on a Nor-Lake Split-Pak walk-in has several auxiliary sensor inputs, and AUX1 is the first of them. Depending on how the system was set up, such an input carries an extra sensor for a job like a second box probe or a monitored point. The controller keeps checking that the input gives a believable temperature. A sensor that has failed shorted reads far below the possible range, and one that has failed open reads far above it, and in either case the controller shows A1A. Nothing about the main box sensors changes, so the cooler or freezer usually keeps working, but whatever depended on AUX1 is running without it. Which function that is depends on how Aux Input 1 was set up on the controller, and that is a question the installer's setup answers, not the display. The alarm clears when the reading becomes usable again, which can happen if a loose connector is reseated.
Affected models and control systems
This applies to the LogiTemp / KE2 Evap OEM controller on Nor-Lake Split-Pak systems with A1 refrigerants, in walk-in coolers and freezers. Other controller generations number their alarms differently.
Code numbers and their meaning can change between control generations. We match the full model and control before acting on a code.
What you may notice
- A1A on the display along with a colored alarm LED
- The box itself holds temperature normally
- An extra monitored point that no longer reports
- Alarm that comes and goes with door traffic or vibration
Possible causes
Listed in Nor-Lake's documentation
- The sensor wired to the AUX1 input
- Its connector and wire run
- The AUX1 input on the controller
- How Aux Input 1 was set up on the controller
Other likely causes — what usually sits behind error code A1A on this control. A technician confirms which one it is before any part is replaced.
- Sensor cable pinched against the evaporator housing or a door frame
- Ice around the connector in a freezer lifting the contacts
- Sensor left connected after the monitored point was removed, so the input now reads open
Safe checks before calling for service
- Note the code and the LED color.
- Check the walk-in temperature with a thermometer to confirm the box itself is fine.
- Look at the door and gasket to be sure the box is sealing.
- If A1A keeps showing, call us to schedule service and tell us when it started.
How a technician diagnoses error code A1A
- Read A1A and the LED state, and confirm which function Aux Input 1 serves.
- Check the sensor and its reading against a reference thermometer.
- With power off, inspect the wire run and connector for pinch, ice or corrosion.
- Measure the sensor resistance and compare with its temperature.
- Test the AUX1 input if the sensor tests good, and replace only the part that fails.
- Sensor wiring runs to the controller board near live voltage, and mistakes can damage the board.
- Telling a bad sensor from a bad input needs a meter and a reference temperature.
- Changing how Aux Input 1 is configured can alter the box's alarms and needs the system's setup data.
How error code A1A differs from similar codes
A2A and A3A are the same alarm for AUX2 and AUX3, so the three codes point at different sensors.
Technical reference
- Document
- LogiTemp Electronic Controller System Operations Manual (171527 Rev. A), Alarms & Notifications List pp. 47-51
- Edition
- 171527 Rev. A, 2025 (Refrigerated Solutions Group)
- Models / control
- LogiTemp / KE2 Evap OEM (Split-Pak systems, A1 refrigerants)
- Section
- Alarms & Notifications List, printed pp. 48-52; Troubleshooting Tables from p. 52
- Checked
- October 2026
We use the maker's document to read the code and do not reproduce it. Always confirm the complete model and control before applying these steps.
Related Nor-Lake walk-in cooler & freezer error codes
Can I keep using the walk-in with A1A?
Usually yes, because the main box sensors are separate. Keep a thermometer in the box and watch it.
Will A1A clear by itself?
It can if a connector was only briefly loose. If it returns, the sensor or its wiring needs testing.
Is A1A the same as A2A?
They are alike but point to different sensor inputs, AUX1 and AUX2.