Nor-Lake Walk-In Error Code dt3: Display Aux3 Sensor Alarm

Dt3 on a Nor-Lake Split-Pak walk-in with a LogiTemp or KE2 Evap controller means the Aux 3 temperature sensor on the combo display is shorted or open. The manual's Troubleshooting Tables from page 52 give the actions.

Medium · inspection needed

Medium: the walk-in should keep cooling, but the Aux 3 monitoring is lost.

Code
Dt3
Maker
Nor-Lake
Equipment
Walk-in coolers & freezers
Applies to
LogiTemp / KE2 Evap OEM controller on Nor-Lake Split-Pak refrigeration systems (A1 refrigerants)

What does Nor-Lake error code Dt3 mean?

Dt3 is the Disp Aux3 Sensor Alarm in the LogiTemp controller's Alarms and Notifications list for Nor-Lake Split-Pak refrigeration systems. The third auxiliary input of the combo display, Aux 3, takes a temperature sensor, and the controller treats a short or an open circuit on that input as a sensor failure. It then shows dt3 and the scrolling text DISPLAY AUX3 SENSOR. The entry in the list is brief: abbreviation, scrolling text and meaning. The manual leaves the corrective actions to its Troubleshooting Tables, which are not reproduced here. So the only things we can say are that the Aux 3 circuit gives no valid reading and that any alarm the controller derives from Aux 3, such as monitor 3 high or low, cannot work while the sensor is out.

Affected models and control systems

Dt3 is listed for the LogiTemp and KE2 Evap OEM controller on Nor-Lake Split-Pak refrigeration systems with A1 refrigerants, in the Alarms and Notifications list printed on pages 48-52, for the Aux 3 input of the combo display.

Code numbers and their meaning can change between control generations. We match the full model and control before acting on a code.

What you may notice

  • Dt3 or DISPLAY AUX3 SENSOR on the display
  • Aux 3 temperature reading missing
  • No Hd3 or Ld3 alarms possible while the sensor is out

Possible causes

Likely causes — what usually sits behind error code Dt3 on this control. A technician confirms which one it is before any part is replaced.

  • Aux 3 sensor wire pulled loose at the display
  • Sensor lead cut where it passes through the box wall
  • Sensor probe failed or wet

Safe checks before calling for service

✓ What an operator can do
  1. Read the main display for the box temperature.
  2. Check for other alarms, especially Hd3 or Ld3.
  3. Do not disconnect the sensor.
  4. Write down dt3 and its scrolling text.
  5. Tell the technician where the Aux 3 sensor is mounted, if you know.

How a technician diagnoses error code Dt3

  1. Read the alarm and confirm it is the Aux 3 input.
  2. Trace and check the sensor wiring.
  3. Measure the sensor resistance against its chart.
  4. Check the controller configuration of the Aux 3 input.
  5. Replace the sensor if it fails.
  6. Confirm dt3 clears and the reading returns.
! Leave this to a technician
  • Terminal and wiring work at the display is near controller power.
  • Sensor assignments are set in the service menu.
  • The replacement sensor must be the right type.

How error code Dt3 differs from similar codes

Dt3 follows the same pattern as dt2, for the Aux 3 input instead of Aux 2.

Technical reference

Document
LogiTemp Electronic Controller System Operations Manual for Split-Pak Refrigeration Systems Containing A1 Refrigerants
Edition
171527 Rev. A, 2025 (Refrigerated Solutions Group)
Models / control
LogiTemp / KE2 Evap OEM controller on Nor-Lake Split-Pak refrigeration systems (A1 refrigerants)
Section
Alarms & Notifications List, printed pp. 48-52; Troubleshooting Tables from p. 52
Checked
October 2026

We use the maker's document to read the code and do not reproduce it. Always confirm the complete model and control before applying these steps.

Dt3Questions about Nor-Lake error code Dt3
Can I keep the walk-in running with dt3?

Yes, cooling does not depend on the auxiliary sensor, though its monitor alarms are off.

Will dt3 go away alone?

Only if the circuit recovers, such as after a loose connector is reseated by a technician.

What sensor is on Aux 3?

The manual entry does not say; the technician can check the installation.