Traulsen G-Series Reach-In and Pass-Thru Refrigerators and Freezers
Current line. 20 model numbers in this series.
Model numbers in this series
Find yours on the data plate. Letters after the base number usually mark the voltage, finish or door and do not change the repair.
- G100
- G110
- G120XX
- G200
- G210
- G220XX
- G300
- G320
- G310XX
- G313XX
- G11010M
- G11011M
- G13010M
- G13011M
- G21010M
- G23010M
- G32010M
- G32011M
- G33010M
- G33011M
Repairs this series usually needs
- HI CAb alarm after a restock or a warm load
- Condenser clean alarm from a clogged coil
- Sensor messages from a cabinet, coil or discharge sensor
- Condensate pan overflow in a humid room
- Frost on the coil from a defrost problem
The G-Series is the current Traulsen reach-in and pass-thru line, sold as refrigerators and as freezers. The data plate shows a series code that runs from G100 and G110 up to the G3 numbers, and glass-door merchandiser versions carry five digits ending in M, such as a G11010M. If your cabinet has a tap-tap keypad, it is this line.
We start with the alarm history and the sensors, since the G control logs what it has seen. Then we look at the condenser, because a dirty coil is the usual reason for a warm cabinet, and at the door gaskets and hump cover. When water collects in the condensate pan, a gasket that leaks humid air is the common reason.
Some newer cabinets use a flammable-class refrigerant, so refrigerant work is left to us.
About this series
- One-, two- and three-section solid-door reach-ins and pass-thrus
- Refrigerator and freezer versions
- G-Series microprocessor control with a tap-tap keypad
- Technician menu with SEn, SEt, AL and SdF
- Series codes from G100 to G313XX on the data plate
Traulsen reach-in refrigerators codes
Other Traulsen reach-in refrigerators series
TB046SL2STB046SL3STB060SL2STB060SL3STB060FL4-1TB065SL2STB065SL3STB071SL2S+3 more→Traulsen R-Series RHT, RLT, RRI and RIF Reach-InsCurrent lineRHT126WUTRHT126WPUTRHT132DUTRHT132NUTRHT132NPUTRHT132WUTRHT132WPUTRHT226WUT+21 more→Traulsen TE Chef BasesCurrent lineTE036HTTE048HTTE060HTTE072HTTE084HTTE096HTTE110HT→Traulsen TS Raised-Rail Prep TablesCurrent lineTS048HTTS066HTTS072HTTS090HT→Traulsen TU Full-Size Undercounter Refrigerators and FreezersCurrent lineTU044HTTU072HTTU100HT→Traulsen UHT and ULT Compact UndercountersCurrent lineUHT27-DUHT32-DUHT48UHT60-DDUHT72-DDULT27ULT48ULT60+1 more→Traulsen UPT and UST Compact Prep TablesCurrent lineUPT276-DUPT279-DUPT3212UPT3212-DUPT4812UPT4818UPT6012UPT6012-DD+16 more→How do I tell a G-Series from an older Traulsen?
Read the series code on the data plate. G-Series cabinets show codes that begin with G and a number, and they use a tap-tap keypad. Older R and A cabinets have a different control.
Why does my G-Series cabinet overflow its condensate pan?
A door gasket or hump cover that does not seal lets in humid air, and a hot room adds load. We check the seals, the pan and the drain.
Is a freezer version serviced the same way?
The control and menu are the same, and we check the same items. A freezer adds electric defrost checks, so we test the heater and its sensor too.
Book repair for your Traulsen G-Series Reach-In and Pass-Thru Refrigerators and Freezers