Traulsen TS Raised-Rail Prep Tables

Current line. 4 model numbers in this series.

01Model numbers

Model numbers in this series

Find yours on the data plate. Letters after the base number usually mark the voltage, finish or door and do not change the repair.

  • TS048HT
  • TS066HT
  • TS072HT
  • TS090HT

Repairs this series usually needs

  1. Cabinet, coil or discharge sensor messages
  2. Clean Filter alarm from a clogged condenser
  3. Warm pans along the rail
  4. Compressor shut down at high discharge temperature
  5. Drain and condensate problems

The TS is the Traulsen raised-rail prep table, with models such as the TS048HT, TS066HT and TS072HT. The number shows the width. The Intela-Traul control prints sensor messages that name the part: CAB Snr for the cabinet sensor, COL Snr for the coil sensor and DIS Snr for the discharge sensor.

That detail speeds the diagnosis. We test the named sensor in a bath of ice and water, then look at the condenser, where grease and lint raise discharge temperature. On the TS, the compressor and fan switch off if discharge goes above 160 F, so a hot kitchen and a dirty coil together can stop the table in the middle of service.

The pan rail keeps its own air flow, and we check it too. The rail has its own air flow above the pans, so we also check that pans sit level and that the cover closes squarely.

About this series

  • Refrigerated raised-rail prep tables
  • Models TS048HT, TS066HT and TS072HT
  • Intela-Traul TE, TU and TS control
  • Sensor messages CAB Snr, COL Snr and DIS Snr
FAQTraulsen TS Raised-Rail Prep Tables questions
What does COL Snr mean?

It is the coil sensor message. The control cannot read the evaporator coil sensor. We test the sensor in ice water and check its wiring.

Why did my table shut off during lunch?

If discharge temperature rose above the safe range, the control stopped the compressor and fan. A dirty condenser and a hot line are the usual causes.

Can you work during service hours?

We plan around your quiet times when you tell us when they are, and we protect the rail while we work. We never ask you to work in a hurry.