Traulsen TS Raised-Rail Prep Tables
Current line. 4 model numbers in this series.
Model numbers in this series
Find yours on the data plate. Letters after the base number usually mark the voltage, finish or door and do not change the repair.
- TS048HT
- TS066HT
- TS072HT
- TS090HT
Repairs this series usually needs
- Cabinet, coil or discharge sensor messages
- Clean Filter alarm from a clogged condenser
- Warm pans along the rail
- Compressor shut down at high discharge temperature
- Drain and condensate problems
The TS is the Traulsen raised-rail prep table, with models such as the TS048HT, TS066HT and TS072HT. The number shows the width. The Intela-Traul control prints sensor messages that name the part: CAB Snr for the cabinet sensor, COL Snr for the coil sensor and DIS Snr for the discharge sensor.
That detail speeds the diagnosis. We test the named sensor in a bath of ice and water, then look at the condenser, where grease and lint raise discharge temperature. On the TS, the compressor and fan switch off if discharge goes above 160 F, so a hot kitchen and a dirty coil together can stop the table in the middle of service.
The pan rail keeps its own air flow, and we check it too. The rail has its own air flow above the pans, so we also check that pans sit level and that the cover closes squarely.
About this series
- Refrigerated raised-rail prep tables
- Models TS048HT, TS066HT and TS072HT
- Intela-Traul TE, TU and TS control
- Sensor messages CAB Snr, COL Snr and DIS Snr
Traulsen reach-in refrigerators codes
Other Traulsen reach-in refrigerators series
G100G110G120XXG200G210G220XXG300G320+12 more→Traulsen Glycol-Cooled Prep TablesCurrent lineTB046SL2STB046SL3STB060SL2STB060SL3STB060FL4-1TB065SL2STB065SL3STB071SL2S+3 more→Traulsen R-Series RHT, RLT, RRI and RIF Reach-InsCurrent lineRHT126WUTRHT126WPUTRHT132DUTRHT132NUTRHT132NPUTRHT132WUTRHT132WPUTRHT226WUT+21 more→Traulsen TE Chef BasesCurrent lineTE036HTTE048HTTE060HTTE072HTTE084HTTE096HTTE110HT→Traulsen TU Full-Size Undercounter Refrigerators and FreezersCurrent lineTU044HTTU072HTTU100HT→Traulsen UHT and ULT Compact UndercountersCurrent lineUHT27-DUHT32-DUHT48UHT60-DDUHT72-DDULT27ULT48ULT60+1 more→Traulsen UPT and UST Compact Prep TablesCurrent lineUPT276-DUPT279-DUPT3212UPT3212-DUPT4812UPT4818UPT6012UPT6012-DD+16 more→What does COL Snr mean?
It is the coil sensor message. The control cannot read the evaporator coil sensor. We test the sensor in ice water and check its wiring.
Why did my table shut off during lunch?
If discharge temperature rose above the safe range, the control stopped the compressor and fan. A dirty condenser and a hot line are the usual causes.
Can you work during service hours?
We plan around your quiet times when you tell us when they are, and we protect the rail while we work. We never ask you to work in a hurry.
Book repair for your Traulsen TS Raised-Rail Prep Tables
Tell us the maker, the model number from the data plate and what the unit is doing. We confirm a three-hour arrival window and give you a written price before any work starts.