Beverage-Air Dual-Temperature Refrigerator-Freezers

Current line. 5 model numbers in this series.

01Model numbers

Model numbers in this series

Find yours on the data plate. Letters after the base number usually mark the voltage, finish or door and do not change the repair.

  • HBRF23HC-1-A
  • HBRF49HC-1-A
  • HBRF49HC-1-A-G
  • HBRF72HC-1-B
  • HBRF72HC-1-B-G

Repairs this series usually needs

  1. Freezer section warm while the refrigerator section is fine
  2. UHi or uLi voltage alarms
  3. Frost in the freezer section
  4. Door gasket wear
  5. Sensor codes

This Beverage-Air group combines a refrigerator section and a freezer section in one cabinet. The prefixes HBRF, WTRF, UCRF and MMRF show the style: bottom-mount, worktop, undercounter and another variant. Models such as HBRF23HC-1-A and HBRF49HC-1-A are in the list.

Two temperatures from one system mean that a small problem shows up in one section first. We check each section’s temperature separately, then the gaskets, the airflow between sections, the fans and the control. The UCRF48AHC is known to show voltage alarms, uHi and uLi, so we measure the supply as well.

Tell us which section is the problem and we start there. After a repair we test both sections again, because a fix on one side can show up as a change on the other.

About this series

  • Refrigerator-freezer combinations
  • Models such as HBRF23HC-1-A and HBRF49HC-1-A
  • Either a Danfoss or an Eliwell electronic controller
  • Five model numbers
FAQBeverage-Air Dual-Temperature Refrigerator-Freezers questions
Why is only the freezer section warm?

The freezer has its own air path and sensor. A blocked vent, a frosted coil or a weak fan affects just that section. We test it against a reference thermometer.

What are uHi and uLi?

They are high and low voltage alarms on the Danfoss control. We measure the supply at the cabinet and check whether the issue is in the building.

Can the two sections be set separately?

Yes. Each has its own set point. We check both against a thermometer. Each section has its own set point, so we confirm both after the repair and before we leave.