Booking today · Miami, Los Angeles, Houston, New York and San Diego · three-hour arrival windows Independent commercial equipment repair · Every maker on this site Mon–Fri 7:00 AM - 8:00 PM · Sat 8:00 AM - 6:00 PM
(844) 393-0816 Schedule a Visit
Model series · Victory · Reach-in refrigerators

Victory RS and RSA Reach-In Refrigerators

Current line. 56 model numbers in this series.

01Model numbers

Model numbers in this series

Find yours on the data plate. Letters after the base number usually mark the voltage, finish or door and do not change the repair.

  • RS(A)-1D-S1-EW-G-HC
  • RS(A)-1D-S1-EW-HC
  • RS(A)-1D-S1-EW-HD-G-HC
  • RS(A)-1D-S1-EW-HD-HC
  • RS(A)-1D-S1-EW-PT-G-HC
  • RS(A)-1D-S1-EW-PT-HC
  • RS(A)-1D-S1-EW-PT-HD-G
  • RS(A)-1D-S1-EW-PT-HD-HC
  • RS(A)-1D-S1-G-HC
  • RS(A)-1D-S1-HC
  • RS(A)-1D-S1-HD-G-HC
  • RS(A)-1D-S1-HD-HC
  • RS(A)-1D-S1-PT-G-HC
  • RS(A)-1D-S1-PT-HC
  • RS(A)-1D-S1-PT-HD-G-HC
  • RS(A)-1D-S1-PT-HD-HC
  • RS(A)-1N-S1-G-HC
  • RS(A)-1N-S1-HC
  • RS(A)-1N-S1-HD-G-HC
  • RS(A)-1N-S1-HD-HC
  • RS(A)-2D-S1-EW-G-HC
  • RS(A)-2D-S1-EW-HC
  • RS(A)-2D-S1-EW-HD-G-HC
  • RS(A)-2D-S1-EW-HD-HC
  • RS(A)-2D-S1-EW-PT-G-HC
  • RS(A)-2D-S1-EW-PT-HC
  • RS(A)-2D-S1-EW-PT-HD-G
  • RS(A)-2D-S1-EW-PT-HD-HC
  • RS(A)-2D-S1-G-HC
  • RS(A)-2D-S1-HC
  • RS(A)-2D-S1-HD-G-HC
  • RS(A)-2D-S1-HD-HC
  • RS(A)-2D-S1-PT-G-HC
  • RS(A)-2D-S1-PT-HC
  • RS(A)-2D-S1-PT-HD-G-HC
  • RS(A)-2D-S1-PT-HD-HC
  • RS(A)-2N-S1-G-HC
  • RS(A)-2N-S1-HC
  • RS(A)-2N-S1-HD-G-HC
  • RS(A)-2N-S1-HD-HC
  • RS(A)-3D-S1-EW-G-HC
  • RS(A)-3D-S1-EW-HC
  • RS(A)-3D-S1-EW-HD-G-HC
  • RS(A)-3D-S1-EW-HD-HC
  • RS(A)-3D-S1-EW-PT-G-HC
  • RS(A)-3D-S1-EW-PT-HC
  • RS(A)-3D-S1-EW-PT-HD-G
  • RS(A)-3D-S1-EW-PT-HD-HC
  • RS(A)-3D-S1-G-HC
  • RS(A)-3D-S1-HC
  • RS(A)-3D-S1-HD-G-HC
  • RS(A)-3D-S1-HD-HC
  • RS(A)-3D-S1-PT-G-HC
  • RS(A)-3D-S1-PT-HC
  • RS(A)-3D-S1-PT-HD-G-HC
  • RS(A)-3D-S1-PT-HD-HC

Repairs this series usually needs

  1. HI or LO temperature alarms
  2. HA and HF HACCP alarms that need a manual reset
  3. Probe codes E1 to E7
  4. Cht and CHt condensing temperature alarms
  5. Dor door-open message

The RS and RSA are the main Victory reach-in refrigerators, in one to three sections with solid or glass doors. Plate numbers follow the pattern RS(A)-1D-S1-HC, where the 1D is one door section. Fifty-six numbers are listed. The VCC controller reports its own codes, which gives us a head start.

On a cabinet like this we read the code, then check the condenser, which should be inspected monthly and cleaned as needed. A cht warning and a CHt alarm tell us the condensing temperature is high, and CHt shuts the compressor off until it is reset. HA and HF are HACCP alarms that stay on until someone clears them, so check the food first.

Current cabinets use R-290, so refrigerant work belongs to a technician. With 56 numbers in the line, the plate number is how we confirm the door style and the gaskets before we arrive.

About this series

  • One- to three-section reach-ins, solid and glass, half and full door
  • Eliwell-type controller on the VCC platform with alarm codes E1 to E7, HI, LO, HA, dor, EHI and ELO
  • Hydrocarbon R-290 refrigerant on current cabinets
  • Condenser coil inspection every month
→Same maker

Other Victory reach-in refrigerators series

Victory ACRS Reach-In RefrigeratorsCurrent lineACRS-1D-S1-G-HCACRS-1D-S1-HCACRS-1D-S1-PT-HCACRS-1D-S1-PT-SD-HCVictory CBR Chef BasesCurrent lineCBR112HCCBR36HCCBR48HCCBR52HCCBR60HCCBR72HCCBR84HCCBR96HCVictory DRS and DRSA Dual-Temperature Reach-InsCurrent lineDRS(A)-2D-S1-HD-HCDRS(A)-2D-S1-LD-HCDRS(A)-2D-S1-PT-HD-HCDRS(A)-2D-S1-PT-LD-HCVictory HS, HSA, HIS and HISA Heated Holding CabinetsCurrent lineHIS(A)-1D-1HIS(A)-1D-1-PTHIS(A)-1D-1-PT-XHHIS(A)-1D-1-XHHIS(A)-2D-1HIS(A)-2D-1-PTHIS(A)-2D-1-PT-XHHIS(A)-2D-1-XH+17 moreVictory LSR Low-Profile RefrigeratorsCurrent lineLSR23HCLSR23HC-IQLSR27HCLSR27HC-IQLSR49HCLSR49HC-IQLSR72HCVictory Older VR and RS-S7 Reach-In Refrigerators2010 eraVR-1VR-2VR-3RS-1D-S7RS-2D-S7RS-3D-S7Victory RFS and RFSA Refrigerator-Freezer Reach-InsCurrent lineRFS(A)-1D-S1-EW-HD-HCRFS(A)-1D-S1-HD-HCRFS(A)-2D-S1-EW-HCRFS(A)-2D-S1-EW-HD-HCRFS(A)-2D-S1-EW-PT-HCRFS(A)-2D-S1-EW-PT-HD-HCRFS(A)-2D-S1-HCRFS(A)-2D-S1-HD-HC+2 moreVictory RIS and RISA Roll-In RefrigeratorsCurrent lineRIS(A)-1D-S1-G-HCRIS(A)-1D-S1-HCRIS(A)-1D-S1-PT-G-HCRIS(A)-1D-S1-PT-HCRIS(A)-1D-S1-PT-XH-G-HCRIS(A)-1D-S1-PT-XH-HCRIS(A)-1D-S1-XH-G-HCRIS(A)-1D-S1-XH-HC+11 moreVictory VERSA Reach-In RefrigeratorsCurrent lineVERSA-1D-GD-HCVERSA-1D-HD-HCVERSA-1D-HG-HCVERSA-1D-SD-HCVERSA-2D-GD-HCVERSA-2D-HD-HCVERSA-2D-HG-HCVERSA-2D-SD-HC+4 moreVictory VPP and VPPD Pizza Prep TablesCurrent lineVPP119HCVPP46HCVPP60HCVPP67HCVPP72HCVPP93HCVPPD119HC-2VPPD119HC-3+21 moreVictory VSP and VSPD Sandwich and Salad Prep TablesCurrent lineVSP27HC-08VSP27HC-12BVSP36HC-10VSP36HC-15BVSP48HC-12VSP48HC-18BVSP60HC-16VSP60HC-24B+20 moreVictory VUR Undercounter RefrigeratorsCurrent lineVUR119HCVUR27HCVUR32HCVUR36HCVUR46HCVUR48HCVUR60HCVUR67HC+22 more
FAQVictory RS and RSA Reach-In Refrigerators questions
What is the difference between cht and CHt?

Lowercase cht is a warning that condensing temperature is high. Capital CHt is the alarm, and the compressor stays off until it is reset. Both point at the condenser.

Why does HA stay on after the cabinet cools?

HACCP alarms are manual reset on purpose. Check the food first, then clear the alarm. If it returns, the cabinet needs a visit. We also look at what caused the warm period.

How often should I clean the condenser?

Inspect it monthly and clean as needed. In a greasy kitchen that often means monthly brushing. Wipe the fins gently with a soft brush and a vacuum, with the cabinet switched off, and call us if grease has hardened on the coil.

Book a visit

Book repair for your Victory RS and RSA Reach-In Refrigerators

Tell us the maker, the model number from the data plate and what the unit is doing. We confirm a three-hour arrival window and give you a written price before any work starts.

☎ Call our office ▤ Schedule a Visit