Victory RS and RSA Reach-In Refrigerators
Current line. 56 model numbers in this series.
Model numbers in this series
Find yours on the data plate. Letters after the base number usually mark the voltage, finish or door and do not change the repair.
- RS(A)-1D-S1-EW-G-HC
- RS(A)-1D-S1-EW-HC
- RS(A)-1D-S1-EW-HD-G-HC
- RS(A)-1D-S1-EW-HD-HC
- RS(A)-1D-S1-EW-PT-G-HC
- RS(A)-1D-S1-EW-PT-HC
- RS(A)-1D-S1-EW-PT-HD-G
- RS(A)-1D-S1-EW-PT-HD-HC
- RS(A)-1D-S1-G-HC
- RS(A)-1D-S1-HC
- RS(A)-1D-S1-HD-G-HC
- RS(A)-1D-S1-HD-HC
- RS(A)-1D-S1-PT-G-HC
- RS(A)-1D-S1-PT-HC
- RS(A)-1D-S1-PT-HD-G-HC
- RS(A)-1D-S1-PT-HD-HC
- RS(A)-1N-S1-G-HC
- RS(A)-1N-S1-HC
- RS(A)-1N-S1-HD-G-HC
- RS(A)-1N-S1-HD-HC
- RS(A)-2D-S1-EW-G-HC
- RS(A)-2D-S1-EW-HC
- RS(A)-2D-S1-EW-HD-G-HC
- RS(A)-2D-S1-EW-HD-HC
- RS(A)-2D-S1-EW-PT-G-HC
- RS(A)-2D-S1-EW-PT-HC
- RS(A)-2D-S1-EW-PT-HD-G
- RS(A)-2D-S1-EW-PT-HD-HC
- RS(A)-2D-S1-G-HC
- RS(A)-2D-S1-HC
- RS(A)-2D-S1-HD-G-HC
- RS(A)-2D-S1-HD-HC
- RS(A)-2D-S1-PT-G-HC
- RS(A)-2D-S1-PT-HC
- RS(A)-2D-S1-PT-HD-G-HC
- RS(A)-2D-S1-PT-HD-HC
- RS(A)-2N-S1-G-HC
- RS(A)-2N-S1-HC
- RS(A)-2N-S1-HD-G-HC
- RS(A)-2N-S1-HD-HC
- RS(A)-3D-S1-EW-G-HC
- RS(A)-3D-S1-EW-HC
- RS(A)-3D-S1-EW-HD-G-HC
- RS(A)-3D-S1-EW-HD-HC
- RS(A)-3D-S1-EW-PT-G-HC
- RS(A)-3D-S1-EW-PT-HC
- RS(A)-3D-S1-EW-PT-HD-G
- RS(A)-3D-S1-EW-PT-HD-HC
- RS(A)-3D-S1-G-HC
- RS(A)-3D-S1-HC
- RS(A)-3D-S1-HD-G-HC
- RS(A)-3D-S1-HD-HC
- RS(A)-3D-S1-PT-G-HC
- RS(A)-3D-S1-PT-HC
- RS(A)-3D-S1-PT-HD-G-HC
- RS(A)-3D-S1-PT-HD-HC
Repairs this series usually needs
- HI or LO temperature alarms
- HA and HF HACCP alarms that need a manual reset
- Probe codes E1 to E7
- Cht and CHt condensing temperature alarms
- Dor door-open message
The RS and RSA are the main Victory reach-in refrigerators, in one to three sections with solid or glass doors. Plate numbers follow the pattern RS(A)-1D-S1-HC, where the 1D is one door section. Fifty-six numbers are listed. The VCC controller reports its own codes, which gives us a head start.
On a cabinet like this we read the code, then check the condenser, which should be inspected monthly and cleaned as needed. A cht warning and a CHt alarm tell us the condensing temperature is high, and CHt shuts the compressor off until it is reset. HA and HF are HACCP alarms that stay on until someone clears them, so check the food first.
Current cabinets use R-290, so refrigerant work belongs to a technician. With 56 numbers in the line, the plate number is how we confirm the door style and the gaskets before we arrive.
About this series
- One- to three-section reach-ins, solid and glass, half and full door
- Eliwell-type controller on the VCC platform with alarm codes E1 to E7, HI, LO, HA, dor, EHI and ELO
- Hydrocarbon R-290 refrigerant on current cabinets
- Condenser coil inspection every month
Victory reach-in refrigerators codes
Other Victory reach-in refrigerators series
ACRS-1D-S1-G-HCACRS-1D-S1-HCACRS-1D-S1-PT-HCACRS-1D-S1-PT-SD-HC→Victory CBR Chef BasesCurrent lineCBR112HCCBR36HCCBR48HCCBR52HCCBR60HCCBR72HCCBR84HCCBR96HC→Victory DRS and DRSA Dual-Temperature Reach-InsCurrent lineDRS(A)-2D-S1-HD-HCDRS(A)-2D-S1-LD-HCDRS(A)-2D-S1-PT-HD-HCDRS(A)-2D-S1-PT-LD-HC→Victory HS, HSA, HIS and HISA Heated Holding CabinetsCurrent lineHIS(A)-1D-1HIS(A)-1D-1-PTHIS(A)-1D-1-PT-XHHIS(A)-1D-1-XHHIS(A)-2D-1HIS(A)-2D-1-PTHIS(A)-2D-1-PT-XHHIS(A)-2D-1-XH+17 more→Victory LSR Low-Profile RefrigeratorsCurrent lineLSR23HCLSR23HC-IQLSR27HCLSR27HC-IQLSR49HCLSR49HC-IQLSR72HC→Victory Older VR and RS-S7 Reach-In Refrigerators2010 eraVR-1VR-2VR-3RS-1D-S7RS-2D-S7RS-3D-S7→Victory RFS and RFSA Refrigerator-Freezer Reach-InsCurrent lineRFS(A)-1D-S1-EW-HD-HCRFS(A)-1D-S1-HD-HCRFS(A)-2D-S1-EW-HCRFS(A)-2D-S1-EW-HD-HCRFS(A)-2D-S1-EW-PT-HCRFS(A)-2D-S1-EW-PT-HD-HCRFS(A)-2D-S1-HCRFS(A)-2D-S1-HD-HC+2 more→Victory RIS and RISA Roll-In RefrigeratorsCurrent lineRIS(A)-1D-S1-G-HCRIS(A)-1D-S1-HCRIS(A)-1D-S1-PT-G-HCRIS(A)-1D-S1-PT-HCRIS(A)-1D-S1-PT-XH-G-HCRIS(A)-1D-S1-PT-XH-HCRIS(A)-1D-S1-XH-G-HCRIS(A)-1D-S1-XH-HC+11 more→Victory VERSA Reach-In RefrigeratorsCurrent lineVERSA-1D-GD-HCVERSA-1D-HD-HCVERSA-1D-HG-HCVERSA-1D-SD-HCVERSA-2D-GD-HCVERSA-2D-HD-HCVERSA-2D-HG-HCVERSA-2D-SD-HC+4 more→Victory VPP and VPPD Pizza Prep TablesCurrent lineVPP119HCVPP46HCVPP60HCVPP67HCVPP72HCVPP93HCVPPD119HC-2VPPD119HC-3+21 more→Victory VSP and VSPD Sandwich and Salad Prep TablesCurrent lineVSP27HC-08VSP27HC-12BVSP36HC-10VSP36HC-15BVSP48HC-12VSP48HC-18BVSP60HC-16VSP60HC-24B+20 more→Victory VUR Undercounter RefrigeratorsCurrent lineVUR119HCVUR27HCVUR32HCVUR36HCVUR46HCVUR48HCVUR60HCVUR67HC+22 more→What is the difference between cht and CHt?
Lowercase cht is a warning that condensing temperature is high. Capital CHt is the alarm, and the compressor stays off until it is reset. Both point at the condenser.
Why does HA stay on after the cabinet cools?
HACCP alarms are manual reset on purpose. Check the food first, then clear the alarm. If it returns, the cabinet needs a visit. We also look at what caused the warm period.
How often should I clean the condenser?
Inspect it monthly and clean as needed. In a greasy kitchen that often means monthly brushing. Wipe the fins gently with a soft brush and a vacuum, with the cabinet switched off, and call us if grease has hardened on the coil.
Book repair for your Victory RS and RSA Reach-In Refrigerators
Tell us the maker, the model number from the data plate and what the unit is doing. We confirm a three-hour arrival window and give you a written price before any work starts.